DEMO MANUAL DC2465A
Quick start proceDure
Refer to Figure 2 for proper equipment setup and follow
the procedure below:
1. Verify that the output voltage of the 3-phase AC source
is within the input voltage range of the DC2465A as
shown in Table 1. Turn off the 3-phase AC source. Con-
nect the 3-phase AC source to VIN1, VIN2, and VIN3
as shown in Figure 2.
2. Connect a load and a voltmeter across VOUT+ to VOUT–
as shown in Figure 2. Turn down the load current to
zero. Put the voltmeter in DC volt measurement mode.
3. Raise the output voltage of the 3-phase AC source to
the desired level. Check the output voltage with the
voltmeter.
4. Raise the load current to desired level. Make sure the
load current is within the maximum load current as
shown in Table 1.
Figure 2. Setup Diagram
DC2447 F03
LOAD
+
–
VOLTMETER
+
–
+–
PHASE 1
+–
PHASE 2
+–
PHASE 3
3-PHASE
AC IN
Table 1. Input Voltage and Output Current Specification
Input Voltage
Maximum Load Current
5VAC to 28VAC RMS (Line to Neutral)
9VAC to 48VAC RMS (Line to Line)
25A
(Without Forced Airflow or Heat sink)