8.  Repeat steps 4 to 6 with V

IN2

. With V

IN1

 off increase 

V

IN2

 from 0V to 8.4V. The part will turn on when V

IN2

 

is approximately 6V. Once on, V

IN2

 can be varied 

between 6V and 8.4V. 8.4V symbolizes a 2-cell Li-Ion 

battery range. However, V

IN2

 is rated for operation up 

to 42V.

9.  Set the load to 5.0Ω (660mA). 
10. Set V

IN2

 to 7.5V and turn on V

IN1

 slowly increasing 

the V

IN1

 voltage from 0V to 10V. Note that V

IN1

 starts 

to supply the power as the voltage of V

IN1

 exceeds its 

turn on set point of 4.3V (see Figure 2).

Quick start proceDure

11. By adjusting the voltage on V

IN1

 from 10V to 0V and 

back the converter operates from V

IN1

 while V

IN1

 is 

above approximately 4.3V and when V

IN1

 is below ap-

proximately 4.2V it operates from V

IN2.

 (See Figure 2).

12. Change JP2 to “DIODE”. By adjusting the voltage on 

V

IN1

 from 10V to 0V and back the converter operates 

from V

IN1

 while V

IN1

 is above approximately 7.5V and 

from V

IN2

 when V

IN1

 is below approximately 7.5V. 

(See Figure. 3).

Содержание DC2215A

Страница 1: ...wn in Figure 1 Burst Mode operation allows the automatic transition to PWM operation if the load current increases ThisisshowninFigure5 MoreinformationonBurstMode operation and PWM mode can be found i...

Страница 2: ...Source of the Converter s Power Is Switched to VIN1 When VIN1 Exceeds the Preset Threshold LOAD CURRENT A 0 0001 0 10 20 30 PERCENTAGE 40 50 100 90 80 70 60 0 001 0 01 0 1 1 10 DC2215A F01 Burst Mode...

Страница 3: ...se Voltages in Ideal Diode Figure 4 Typical 2 2A to 45mA to 2 2A Load Transient on a 3 3V Output with VIN 12V 2ms DIV DC2215A F03 VOUT 1V DIV VIN2 2V DIV VIN1 2V DIV TRANSITION TO VIN1 TRANSITION TO V...

Страница 4: ...peration and Transitioning from and into Burst Mode Operation 2ms DIV DC2215A F05 PWM OPERATION 100mV DIV Burst Mode RIPPLE AUTOMATIC TRANSITION FROM Burst Mode TO PWM AUTOMATIC TRANSITION FROM PWM TO...

Страница 5: ...exceed 42V GND Ground connection for input supply VIN2 6V to 8 4V supply input operational to 42V Right side of board GND Ground connection for LOAD VOUT 3 3V 2 5A first of two terminals in parallel V...

Страница 6: ...VIN1 voltage from 0V to 10V Note that VIN1 starts to supply the power as the voltage of VIN1 exceeds its turn on set point of 4 3V see Figure 2 Quick Start Procedure 11 By adjusting the voltage on VIN...

Страница 7: ...7 dc2215af DEMO MANUAL DC2215A Figure 6 Measurement Setup Quick Start Procedure...

Страница 8: ...k 1 1 10W 0402 PANASONIC ERJ 2RKF7873X 13 1 R10 RES 215k 1 1 10W 0402 PANASONIC ERJ 2RKF2153X 14 1 R11 RES 732k 1 1 10W 0402 PANASONIC ERJ 2RKF7323X 15 1 R12 RES 309k 1 1 10W 0402 PANASONIC ERJ 2RKF30...

Страница 9: ...TOMER SUPPLIED SPECIFICATIONS HOWEVER IT REMAINS THE CUSTOMER S RESPONSIBILITY TO VERIFY PROPER AND RELIABLE OPERATION IN THE ACTUAL APPLICATION COMPONENT SUBSTITUTION AND PRINTED CIRCUIT BOARD LAYOUT...

Страница 10: ...ORY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTA...

Страница 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2215A...

Отзывы: