background image

5

dc2025afa

DEMO MANUAL DC2025A

Information  furnished  by  Linear  Technology  Corporation  is  believed  to  be  accurate  and  reliable.  

However, no responsibility is assumed for its use. Linear Technology Corporation makes no representa-

tion that the interconnection of its circuits as described herein will not infringe on existing patent rights.

QUICK START PROCEDURE

Table 1

MSP2

MSP1

MSP0

OUTPUT RANGE

RESET CODE

MANUAL SPAN

SoftSpan

0

0

0

±10V

Mid-Scale

X

0

0

1

±5V

Mid-Scale

X

0

1

0

±2.5V

Mid-Scale

X

0

1

1

0V to 10V

Zero-Scale

X

1

0

0

0V to 10V

Mid-Scale

X

1

0

1

0V to 5V

Zero-Scale

X

1

1

0

0V to 5V

Mid-Scale

X

1

1

1

0V to 5V

Zero-Scale

X

Jumpers
REF_SEL (JP1):

  Selects  internal  or  external  reference 

mode. (See data sheet description of REFCOMP pin.)

MSP0,  MSP1,  MSP2 (JP2,  JP3,  JP4):

  Manual  Span 

control.  Setting  all  jumpers  to  the 1 position (Default) 

selects SoftSpan operation, with a power-up default span 

of 0V to 5V, and reset to Zero-Scale. Other options are 

listed in Table 1.

LEDs
OVRTMP:

 Lights when 

OVRTMP

 pin asserts, indicating an 

overtemperature state. (Note that LED will light if positive 

analog supply is present and OVP is not. OVP is normally 

supplied by the controller.)

Test Points

The SPI bus is available on a row of through-hole test 

points next to J1 that may be used to monitor the bus or 

to drive the bus with an external controller.

EEGND, WP:

 For factory use only.