![Linear Technology DC1936A Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/linear-technology/dc1936a/dc1936a_demo-manual_1922294007.webp)
7
dc1936afa
DEMO MANUAL DC1936A
LTpowerPlay QUICK START PROCEDURE
The following procedure describes how to use LTpowerPlay
to monitor and change the settings of LTC3882.
1. Download and install the LTPowerPlay GUI:
http://linear.com/ltpowerplay
2. Launch the LTpowerPlay GUI.
a. The GUI should automatically identify the DC1936A.
The system tree on the left hand side should look like
this:
b. A green message box shows for a few seconds in the
lower left hand corner, confirming that the LTC3882
is communicating:
c. In the Toolbar, click the R (RAM to PC) icon to read the
RAM from the LTC3882. This reads the configuration
from the RAM of LTC3882 and loads it into the GUI.
d. If you want to change the output voltage to a different
value, like 1.5V. In the Config tab, type in 1.5 in the
VOUT_COMMAND box, like this:
Then, click the W (PC to RAM) icon to write these reg-
ister values to the LTC3882. After finishing this step,
you will see the output voltage will change to 1.5V.