background image

2

dc1883Af

DEMO MANUAL DC1883A

Quick start proceDure

Using short twisted-pair leads for any power connections 

and with all loads and power supplies off, refer to Figure 3 

for the proper measurement and equipment setup. The 

battery/power supply (PS1) should not be connected to 

the circuit until it is stated in the following procedure.

When measuring the input or output voltage ripple, care 

must be taken to avoid a long ground lead on the oscil-

loscope probe. Measure the input or output voltage ripple 

by touching the probe tip directly across the V

IN

 or V

OUT

 

and GND terminals (see Figure 4), or by using an oscil-

loscope probe tip jack. 
1. Jumper, PS1 and LOAD settings to start:
  PS1 = OFF 
  JP1 (RUN) = OFF 
  JP2 (MODE) = FIXED FREQUENCY      

 

2. With power off, connect the power supply (PS1) as 

shown in Figure 3. If accurate current measurements 

are desired (for efficiency calculation for example), 

then connect an ammeter in series with the supply as 

shown. The ammeter is not required, however.

3. Connect a load to V

OUT

, as shown in Figure 3. The load 

can be up to 300mA or 6Ω for V

OUT

 = 1.8V. Connect an 

ammeter if accurate current measurement or monitoring 

is desired. 

4. Turn on PS1 and slowly increase voltage until the volt-

age at V

IN

 is 5V. Move Jumper JP1 to ON. 

5. Verify V

OUT

 is ~1.8V.  

6. V

IN

 can now be varied between 3V and 15V. V

OUT

 should 

remain in regulation.

7. V

IN

 can also be varied down to 2.5V. For V

IN

 ≤ 3V,  

V

OUT

 may drop out of regulation, as previously de-

scribed.

8. I

OUT

 can also be varied from 0mA to 300mA.

9.  For Burst Mode operation, move jumper JP2 to BURST.  

See the data sheet for more information.

NOTES:
(1) If V

OUT

 drops out of regulation, check to be sure  

the maximum load has not been exceeded, or that V

IN

 is  

not below the minimum value for regulation (see  

the data sheet). 

(2) To measure no-load input current, remove R4.

V

IN

 (V)

3

50

EFFICIENCY (%)

55

65

70

75

100

85

7

11

13

60

90

95

80

5

9

15

dc1883a F01

300mA LOAD

100mA LOAD

V

IN

 (V)

3

50

EFFICIENCY (%)

55

65

70

75

100

85

7

11

13

60

90

95

80

5

9

15

dc1883a F02

5mA LOAD

1mA LOAD

10mA LOAD

Figure 1. DC1883A Efficiency in PWM Mode

Figure 2. DC1883A Efficiency in Burst Mode Operation

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Отзывы: