6
dc1774acf
DEMO MANUAL DC1774A-C
ADDITIONAL INFORMATION
Figure 7. Proper Equipment Setup for Gain and Single-Tone Measurement
SPECTRUM
ANALYZER
SIGNAL
GENERATOR
(HP8644A)
ROHDE AND
SCHWARZ
FSEM30
COAXIAL CABLE
LOWPASS
FILTER
(OPTIONAL)
3dB
ATTENUATION PAD
(OPTIONAL)
ASSY
U1
FREQ
-A
LTC6430IUF-15
100MHz TO 300MHz
-B
LTC6430IUF-15
400MHz TO 1000MHz
-C
LTC6431IUF-15
100MHz TO 1200MHz
DC POWER SUPPLY
GND
V+
Figure 6. IMD Buried in the Noise Floor
Figure 5. Not Enough Input Attenuation
+2dBm
~ –80 dBm
Noise Floor at
~ –101dBm
+2dBm
Noise Floor at
~ –81dBm