5
dc1385af
DEMO MANUAL DC1385A
Figure 4. Measured Load Transient Response for V
OUT1
Figure 5. Measured Load Transient Response for V
OUT2
QUICK START PROCEDURE
V
OUT1
(20mV/DIV)
I
OUT1
STEP (2A/DIV)
V
IN1
= 5V
V
OUT1
=1.8V
CONTINUOUS CURRENT MODE (CCM)
1A TO 4A LOAD STEP ON V
OUT1
C
OUT1
= 100μF CERAMIC (1210, X5R, 6.3V) + 22μF CERAMIC (1206, X5R, 6.3V)
V
OUT2
(20mV/DIV)
I
OUT2
STEP (2A/DIV)
V
IN2
= 5V
V
OUT2
=1.2V
CONTINUOUS CURRENT MODE (CCM)
1A TO 4A LOAD STEP ON V
OUT2
C
OUT2
= 100μF CERAMIC (1210, X5R, 6.3V) + 22μF CERAMIC (1206, X5R, 6.3V)