Linear Technology DC1210A Скачать руководство пользователя страница 3

 

 

LTC4090 

 

9.

 

Test  of  the  H VIN  input  overvoltage  protection:  In-
crease the  H VIN  input voltage slow ly  and  note  that 
as the voltage exceeds 38V… 45V the input current 
w ill  drop  to  zero  indicating  that  the  buck  regulator 
shut dow n due to overvoltage. The System Load is 
now   pow ered  from  the  battery  (and  from  U SB  if 

available).  Decrease  the  H VIN  voltage  and  observe 
that the buckregulator w ill resume normal operation. 

10.

 

Increase  the  battery  voltage  and  note  that  the 

charge  current  falls  to  zero  w hen  the  voltage  ex-
ceeds 4.167V… 4.215V.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                              

 

 

                                                     Figure 1. Proper M easurement Equipment Setup 

Отзывы: