FACTORY DEFAULTS

MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123456
ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-EXIT OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MAIN RELAY
ALARM SHUNT OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #3
DOOR AJAR OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #4
MAIN RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
AUXILIARY RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #3 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #4 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
KEYPAD LOCKOUT COUNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO ANTI-PASSBACK
AUTO-RELOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ON

BASIC PROGRAMMING

When the AK-31 is in Programming Mode, both indicators will turn 
off until programming begins. After a programming option number 
is entered the yellow indicator will blink. This shows that the AK-31 
is ready to accept the new programming data. After the new data 
entry is complete, the yellow indicator will fl ash while the data is 
being stored. The green indicator will light if the data is accepted. 
The red indicator will light if any programming data is entered 
incorrectly, and the command will have to be fully re-entered.

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used to enter 
Programming Mode.

Press:

  

# 9 #

 

Master Code

 

Master Code

 = the current 6-digit Master Programming Code

Exiting Programming Mode

Press: 

 

*

 

*

 

#

The red indicator will light after exiting Programming Mode.

 

NOTE: 

The AK-

3

1 will automatically exit Programming Mode after two 

minutes of inactivity.

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an incorrect key is 
pressed during programming, to clear the keypad and re-enter the command:

Press: 

 

*

 

9 #

Setting Entry Code Length 

Default: 4 digits

Press:

  

3

 

#

 

Length

 

#

Length

 = 1 - 6 for entry code length

 

NOTE: If the Entry Code Length is going to be changed from the factory 
default of four digits, make this change fi rst, before programming any 
entry codes.

Adding a New Entry Code

Press: 

01 # Code # Code # Action #

Code = The new entry code: 1-999999, depending on code length

Action = Relay output entry code will activate as follows:

 

  1 = Relay #1, timed open

 

  2 = Relay #2, timed open

 

  3 = Both Relays, timed open

 

10 = Relay #1, toggled

 

20 = Relay #2, toggled

 

30 = Both Relays, toggled

 

12 = Relay #1 toggled; Relay #2, timed open

 

21 = Relay #1 timed open; Relay #2 toggled

The yellow LED will fl ash quickly while the AK-31 searches its 
memory for available space and duplicate entries. The green LED 
will light when the new code is stored. 
If the new entry code chosen is already being used for another 
entry code, the red LED will light. A new 

unique

 code needs to be 

entered.

☞ 

NOTE:

 Leading zeros (zeros before the code number, i.e. 0001) do not need 

to be entered when programming a new entry code. The AK-

3

1 will internally 

add any zeros to fi ll all digits determined by the entry code length setting. 
Leading zeros 

will

 have to be entered by the user when entering their code 

to gain access.

Erasing a Single Entry Code

Press:

  

0 2 #

 

Code

 

#

 

Code

 

#

Code

 = The entry code to delete.

The yellow indicator will fl ash quickly while the AK-31 searches its 
memory for the code to erase. The green indicator will light when 
the code is erased.

Erasing All Entry Codes

  WARNING: PERFORMING THIS COMMAND WILL 

REMOVE ALL ENTRY CODES FROM THE MEMORY.

Press:

  

9 7 # 0 0 0 0 0 0 # 0 0 0 0 0 0 #

 

NOTE:

 The green indicator will light while the memory is being erased. This 

may take up to 15 seconds.

Changing the 6-Digit Master Programming Code

Press:

  

9 8 #

 

Master Code

 

#

 

Master Code

 

#

Master Code

 = The new 6-digit Master Programming Code

New master code: _____________________

228037 A     IMAGE 6

Содержание AK-31

Страница 1: ...1 2 3 4 5 6 7 8 9 0 AK 31 Digital Keyless Entry System 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation and Programming Instructions ...

Страница 2: ...s and programming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid state outputs capable of switching 100 mA to common are programmable to signal forced entry door ajar lockout alarm circuit shunting request to exit and keypad active conditions FEATURES KEYPAD PROGRAMMABLE No programmer...

Страница 3: ...DC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 1 WIRES AK 31 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF THE SYSTEM TRANSFORMER IS ISOLATED FROM EARTH GROUND OPTIONAL WIRING REQUIRED WIRING OTHER WIRING NOTES 1 ALARM SHUNT SET FOR AUXILIARY RELAY 2 GRAY WIRE SET FOR DOOR SENSE GROUND STAKE N C DOOR SWITCH ALARM CONTACT TO ALARM SYSTEM POWER SUPPLY ELECTRIC DOOR S...

Страница 4: ...in the wall Screw the mounting plate onto the electrical box see Figure 4 Final Keypad Installation After wiring the keypad see next page complete the installation by securing the keypad to the mounting plate If a lower beeper sound level is required before installing the keypad remove Jumper at P4 place the jumper block on one pin to save the jumper Hook the keypad assembly onto the mounting plat...

Страница 5: ...e switch to the keypad box Connect the door switch to the keypad s SENSE input gray wire E8 and COM any black wire If an inhibit switch or timer is going to be used for temporarily disabling the keypad route two wires from the switch or timer to the keypad box Connect the inhibit switch timer normally open terminals to the keypad s SENSE input gray wire E8 and COM any black wire REQUEST TO EXIT IN...

Страница 6: ... during programming to clear the keypad and re enter the command Press 9 Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry code length NOTE If the Entry Code Length is going to be changed from the factory default of four digits make this change first before programming any entry codes Adding a New Entry Code Press 01 Code Code Action Code The new entry code 1 999999 ...

Страница 7: ...o 2 seconds Press 1 4 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output to shunt alarm contacts attached to the access door This output may be timed or toggled Press 1 5 Output Output Output to Activate 0 4 1 Main Relay 2 Auxi...

Страница 8: ...maximum ENVIRONMENTAL Temperature 22 F to 149 F 30 C to 65 C Humidity 5 to 95 non condensing LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty four 24 months The Warranty Expiration Date is labeled on the product This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels...