22
DO7325F
EN
object that is obstructing the grids. Then switch it back on as described above. The appliance should
operate normally. Should the problem persist, please contact the nearest customer service.
· The appliance is also equipped with a tip-over safety, which is integrated in the appliance. The
appliance will turn off when it tips over.
CLEANING AND MAINTENANCE
· Before cleaning the appliance, ensure it is disconnected from the power supply and has cooled down
completely.
· To avoid the risk of electric shock, do not clean the heater with water and do not immerse it. Clean the
housing with a damp cloth.
· If necessary, dust particles accumulated in the air outlet openings may be removed with a vacuum
cleaner. This maintenance should be done regularly to assure the good operation of the appliance.
Dust particles in the appliance may cause over-heating.
· Allow the unit to cool down completely before storing it.
· Store the appliance in a clean and dry place.
· You can easily move the device thanks to the handles.
SPECIFICATIONS
Model identifier(s): DO7325F
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage
local space heaters only
Nominal heat output
Pnom
1,86
kW
manual heat charge control,
with integrated thermostat
N/A
Minimum heat output
(indicative)
Pmin
0,956
kW
manual heat charge control
with room and/or outdoor
temperature feedback
N/A
Maximum continuous
heat output
Pmax
1,86
kW
electronic heat charge control
with room and/or outdoor
temperature feedback
N/A
Auxiliary electricity
consumption
---
---
---
fan assisted heat output
N/A
At nominal heat
output
elmax
N/A
kW
Type of heat output/room temperature
control
At minimum heat
output
elmin
N/A
kW
single stage heat output and
no room temperature control
N/A
In standby mode
elSB
0,0
KW
Two or more manual stages,
no room temperature control
N/A
with mechanic thermostat
room temperature control
Yes
with electronic room
temperature control
N/A