36
DO158A
EN
STORAGE
· Empty and dry the water reservoir.
· Make sure the honeycomb filter is dry before storing it. See drier function below.
· Wrap the device so that dust cannot get inside.
· You can use the water reservoir fastener clips to hold the cord.
Drier function
The cooler/humidifier function pumps water to the honeycomb filter. We recommend that you allow the
filter to dry after use for reasons of hygiene and to extend its service life. To turn on the drier function, do
the following:
· Press the speed button for 3 seconds.
· The speed will flash on the display.
· The drier function lasts 20 minutes and then automatically turns off. The other buttons do not work
while this function is activated.
· If you want to turn the drier function off earlier, press the on-off button. You cannot then restart the
drier function. If you want to use the drier function again, you must start from the beginning.
SPECIFICATIONS
Model identifier(s): DO158A
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage
local space heaters only
Nominal heat output
Pnom
2.000
kW
manual heat charge control,
with integrated thermostat
N/A
Minimum heat output
(indicative)
Pmin
1.181
kW
manual heat charge control
with room and/or outdoor
temperature feedback
N/A
Maximum continuous
heat output
Pmax
1.929
kW
electronic heat charge control
with room and/or outdoor
temperature feedback
N/A
Auxiliary electricity
consumption
---
---
---
fan assisted heat output
N/A
At nominal heat
output
elmax
N/A
kW
Type of heat output/room temperature
control
At minimum heat
output
elmin
N/A
kW
single stage heat output and
no room temperature control
No
In standby mode
elSB
0.00026
KW
Two or more manual stages,
no room temperature control
No
with mechanic thermostat
room temperature control
No
with electronic room
temperature control
Yes