Troubleshooting

Please follow the instructions in this manual to keep the amplifier working in a reliable and safe manner. 
If problems arise or you think there is a problem , please first check the tips given below to checkfor the excact reason.
Sometimes problems could be caused by other related equipment , please check the connections . After doing so and 
the problem still exists , please contact our factory or your local dealer.

Problem

Cause

Remedy 

NO OUTPUT

Power LED is ON.

Power LED is OFF.

Power cord is not well-connected

Main fuse is out.
Troubles of inner parts 
or components

Please check the power cable connection or 
power outlet connection
Replace with the same type and value fuse
Please contact your local agents 
or our factory

NO signal input

Volume is at ZERO

Turn up the Volume

Check the function of the sound source
Check the input connectors and/or
 switch to the proper input

NO reaction to the remote

Stereo image

is not so good

Noise output

Sound Distortion

High input signal level

Ground of input signal cable is 
open or bad contact of the input 
signal cable
Components or circuits are 
in trouble
Signal input cables or speaker 
cables are wrongly connected

Disturbed by external instruments

Battery is low
Obstacle is located between the 
remote and the amplifier

Turn down the volume to suitable position

Replace the input signal cable with a 
new one

Please contact with local dealer or 
our factory

Reconnect it as suggested in the manual

Keep away from the disturbance and 
restart the amplifier.
Please replace the bateries 

Remove the obstacle

Line Magnetic logo                         is registered trademark of  Zhuhai Line Magnetic Audio Co., LTD. 
Copyright of Zhuhai Line Magnetic Audio Co., LTD. All Rights Reserved.

Содержание LM-217IA

Страница 1: ...INTEGRATED VACUUM TUBE AMPLIFIER LM 217IA...

Страница 2: ...your amplifier to avoid any risks 01 Table of Contents Table of Contents Package Contents Product Features Specification Safety Precautions Functions Description Connection Turning on Remote Control T...

Страница 3: ...o high voltage can cause serious damage to your amplifier In case you find an improper voltage please contact our company or your local dealer Product features Hand made construction with the finest p...

Страница 4: ...en to operate as unloaded 4 Forbidden to operate when the output is open or shorted 5 Do not attempt to service this product yourself Opening the cover may expose you to dangerous voltage or other haz...

Страница 5: ...ualified service personnel To reduce the risk of fire or electronic shock do not expose the unit to rain or moisture Note Input voltage level of the amplifier is 230VAC 5 and please make sure that the...

Страница 6: ...o connect with the right channel of the speakers 1 Signal Inputs used for source input 4 Power Socket with main fuse Main fuse is located on the rear of the amplifier just below the power cord socket...

Страница 7: ...lifier and wait for around ten minutes Choose and turn the Bias current knob to V1 and then adjust V1 BIAS ADJ Inspect the ampere meter on the front panel If you have any questions please contact with...

Страница 8: ...right channel connections don t mix them up as this will cause noise and badstereo imaging How to connect the speaker cables 1 Unscrew the terminal knobs 2 Insert the speaker cables 3 Screw the termin...

Страница 9: ...noise or low grade function 5 Do not fasten signal cables together with other cables just like the power cables to avoid disturbance 08 Connection Turning ON Before turning on the amplifier please mak...

Страница 10: ...well connected 4 To prevent damage to the amplifier never cut off the speaker cables while the unit is ON 5 In order to protect the tubes please re switch on the amplifier after turned off in two min...

Страница 11: ...ase check the indicators giving for the correct positioning 3 Re assemble the remote Remote Control Description VOLUME UP VOLUME DOWN MUTE Replacement 1 When the batteries are low please replace them...

Страница 12: ...in original packaging and returned to Zhuhai Line Magnetic Audio Co LTD or an authorized Line Magnetic Audio Representative at his or her sole expense A returned product must be accompanied by a writt...

Страница 13: ...olume is at ZERO Turn up the Volume Check the function of the sound source Check the input connectors and or switch to the proper input NO reaction to the remote Stereo image is not so good Noise outp...

Отзывы: