Lindy KVM EXTENDER 32357 Скачать руководство пользователя страница 5

English Manual   

 

 

 

 

 

 

 

        

 

5

 

 

Operation 

Selecting and using computers  

To select a system using the keyboard: 

Use the hotkey to switch between the two computer systems. In each case, you need to 

simultaneously press the currently configured hotkeys (by default, CTRL and SHIFT) together 

with the number of the required system 1 or 2. 

To disconnect from both systems press the hotkeys followed by 0. 

 

Locking and unlocking the system 

In situations where the computer systems (and their local CAMs) can be locked away, the USB 

User Station offers a security system to deter unauthorised use. Once a password has been set, 

a simple key sequence allows each system to be quickly and securely detached from the 

common peripherals. Only the correct password will reconnect the modules. 

To lock the system 

1.  First set a password. For further details, please refer to the Password setting section. 

2.  Simultaneously press the currently configured hotkeys followed by L. 

The screen will go blank and the three keyboard indicators will begin alternately flashing 

between the ‘Num Lock’ and ‘Scroll Lock’, and ‘Caps Lock’. This sequence indicates that a 

password is required. Additionally neither of the green indicators adjacent to the RJ45 

connectors on the User Station will be lit. 

To unlock the system 

1. 

Enter the correct password and press RETURN. 

Note 1: Passwords are NOT case sensitive. 

Note 2: If an invalid password has been entered and the keyboard indicators are not flashing 

as described above, press RETURN to clear the incorrect attempt.  

2.  If the correct password is entered, the screen will be restored and normal operation can 

continue. 

 

Password setting 

Password protection allows you restrict access to the USB User Station.  

To set a password 

1.  Simultaneously, press the hotkeys followed by RETURN to enter configuration mode. 

2.  Press P followed by RETURN. 

3.  Now enter your new password, within the following constraints: 

• Passwords are NOT case sensitive, 

• Passwords may be any length from one character to a maximum of forty characters, 

• The following keys may NOT be used: CTRL, ALT, SHIFT or  RETURN. 

4.  When you have entered the password, press RETURN to signal its completion. 

5.  Press RETURN once more to exit configuration mode.  

 

To clear a password (and restore factory default settings) 

1.  Connect the User Station to a computer by one USB port only. 

2.  While power is applied, set the units upgrade switch SW1 to its ON position. 

3.  Remove power from the unit and then re-apply power. 

4.  Set the computer serial settings to the following: 19200, n, 8, 1 

5.  Using a terminal program, send “CLEAR<cr>” - in upper or lower case from the keyboard. 

The User Station should respond with “OK”. 

6.  The password is now clear and all factory default settings restored. 

 

Содержание KVM EXTENDER 32357

Страница 1: ...DY ELEKTRONIK GMBH SECOND EDITION FEB 2008 Tested to Comply with FCC Standards For Commercial Use Only KVM Extender User Station Cat 5 KVM Extender User Manual English LINDY No 32357 32358 32359 LINDY...

Страница 2: ...th its own power adapter and country specific power lead KVM Extender User Station C5 Junior Part number 32357 For PS 2 keyboard mouse and VGA up to 200m distance Connectors VGA HD15 analog video PS 2...

Страница 3: ...art number 39355 Connectors VGA HD15 analog video Sun keyboard mouse and 3 5mm audio jack Remote user via User Station A remote User Station can be placed at a maximum of 300 metres from the MC5 unit...

Страница 4: ...be affected by the DIP switches on the USB User Stations Switch 1 OFF Normal operation ON Flash Upgrade switch before Power is applied Switches 2 and 3 determine which two keyboard keys are used 2 OFF...

Страница 5: ...k the system 1 Enter the correct password and press RETURN Note 1 Passwords are NOT case sensitive Note 2 If an invalid password has been entered and the keyboard indicators are not flashing as descri...

Страница 6: ...ent and combats the effect of uneven twisted pairs within link cables See Remote user skew adjustment for details Remote user video compensation Video compensation for each remote user is provided by...

Страница 7: ...ser Station C5 Pro module only To apply remote user video compensation 1 When used with a KVM Switch MC5 first ensure that the video image from the computer to the KVM Switch has been correctly compen...

Страница 8: ...nd blue lines are rendered exactly on the screen as single pixel wide lines The skew bmp test pattern can also be used but it is less accurate Alternatively you can create your own skew pattern using...

Страница 9: ...ck for Red Caps Lock for Green and Scroll Lock for Blue 4 Press the and keys to retard or advance the timing of the selected colour channel respectively On screen you will see a change in the position...

Страница 10: ...o maintain EMC compatibility Dieses Produkt entspricht den einschl gigen EMV Richtlinien der EU und darf nur zusammen mit abgeschirmten Kabeln verwendet werden LINDY Herstellergarantie LINDY gew hrt f...

Отзывы: