A new firmware update is a binary file which can be sent to you by email or which you can
download from our website
www.lindy.com
.
Updating the firmware is a three-stage process:
1. The new firmware file is uploaded to the IP ACCESS SWITCH LITE. In order to do this you
need to select the file on your local system using the
Browse
button on the Upload
Firmware panel. Once the firmware file has been uploaded it is checked whether it is a valid
firmware file and whether there were any transmission errors. In case of any error the
Upload Firmware function will be aborted.
2. If everything went well you will see the Update Firmware panel. The panel shows you the
version number of the currently running firmware and the version number of the uploaded
firmware. Pressing the
Update
button will replace the old version with the new one.
Note:
This process is not reversible and may take some minutes. Make sure the IP ACCESS
SWITCH LITE’s power supply will not be interrupted during the update process.
3. After the firmware has been stored, the panel will request you to reset the IP ACCESS
SWITCH LITE manually. Half a minute after the reset the IP ACCESS SWITCH LITE will run
with the new firmware version and should be accessible. However, you will be required to
login once again.
Note:
The three-stage firmware update process and consistency check means that making a
mistake when updating the firmware is very unlikely. However, we recommend only
experienced users or administrators should perform the firmware update. Make sure the IP
ACCESS SWITCH LITE’s power supply will not be interrupted during the update process!