background image

P/N 1604010 Rev D (ECN 35207) 

1-1 

Multi-Control Operation Manual

 

 

Section 1- Specifications and Compliance

Section 1- Specifications and Compliance

Requirements for Electrical Service

All electrical equipment shall be installed by a qualified electrician. As a result, a correct installation will allow the 

irrigation system to protect itself from overloads and ground faults with minimal downtime, or possible damage and 

hazards.

Refer to ANSI, ASAE Standard S397.2 (latest revision) Electrical Service and Equipment for Irrigation for exact 

requirements.

Compliance Standards

Federal Communications Commission (FCC) Statement

NOTE:

 This equipment has been tested and found to comply within the limits for a Class B digital device pursuant 

to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer-

ence when the equipment is operated in a commercial environment. This equipment generates, uses and radiates 

radio frequency energy and, if not used in accordance with the manufacturer’s instruction manual, may cause 

harmful interference with radio communications. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1.  This device may not cause harmful interference.

2.  This device must accept any interference received, including interference that may cause undesired operation.

These limits are designed to provide reasonable protection against harmful interference. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer-

ence with radio or television reception, which can be determined by turning the equipment on and off, try  to cor-

rect the interference by one or more of the following measures:

•  Reorient or relocate the antenna of the radio/television receiver.

•  Increase the separation between this equipment and the radio/television receiver.

•  Plug the equipment into a different outlet so that the equipment and the radio/television receiver are on different 

power main branch circuits.

•  Consult a representative of Lindsay Corporation for additional suggestions.

Industry Canada Compliance Statement

This Class B digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regula-

tions.

Cet appareil numerique de la Classe B respecte toutes les exigences du Relement sur le Materiel Brouilleur du 

Canada.

WEEE Statement

Lindsay Manufacturing, LLC products: D012-007-20 MC Panel; D012-007-11 MC Panel, 2.4 GHz; D012-007-14 

MC Expansion Panel; D012-007-22 WS Panel and D012-007-13 WS Panel, 2.4 GHz are sold and distributed in 

the European Union only by:

Lindsay Europe SAS

L’Epinglerie

72 300 La Chapelle d’Aligne

France

Phone: 33 (0)2 43480205

Содержание GrowSmart Multi-Control

Страница 1: ...Multi Control Operation Manual P N 1604010 Rev D ECN 35207...

Страница 2: ......

Страница 3: ...or serious injury Orange Black Indicates a hazardous situation that if not avoided could result in death or serious injury Yellow Black Indicates a hazardous situation that if not avoided could result...

Страница 4: ...s WARNING Main Disconnect The main power disconnect is located at the main service breaker or generator The disconnect at the panel is not the main disconnect A fusible service disconnect device must...

Страница 5: ...fore performing any maintenance Never lubricate or service machine while it is moving Keep hands feet and loose clothing from power driven parts Disengage all power and operator controls to relieve pr...

Страница 6: ...ssion sound pressure level at the pivot point does not ex ceed 70 dB Eye Protection Sharp Objects debris and explosions can cause severe eye damage or blind ness Wear Safety Standard approved protecti...

Страница 7: ...her individual or mechanical lifting device Do not work or stand under system or components during assembly Due to the weights involved severe injury or death can result if components should fall WARN...

Страница 8: ...6 Standard Controls General Safety Instructions Earth Ground Protective Earth Ground Frame or Chassis Ground The following symbols indicate grounding connections that can be found on irrigation syste...

Страница 9: ...l Communications Commission FCC Statement 1 1 Industry Canada Compliance Statement 1 1 WEEE Statement 1 1 Product Specifications 1 2 Dimensional Data and Weight 1 3 Service 1 4 Panels Panel ID Locatio...

Страница 10: ...P N 1604010 Rev D ECN 35207 Multi Control Operation Manual Table of Contents...

Страница 11: ...ce must accept any interference received including interference that may cause undesired operation These limits are designed to provide reasonable protection against harmful interference However there...

Страница 12: ...available at local City Government Offices or by contacting Lindsay Europe SAS Contact Lindsay Europe SAS with any questions or assistance with returning MC Panels MC Expansion Panels or WS Panels Pro...

Страница 13: ...ll input and output devices shall have a minimum basic insulation Wireless Switch WS Panel Ratings 2000 Meters Altitude 3 3 1 Amps Lithium Iron Phosphate LiFePPO4 3 2V 10 2 Watt Hours IP44 Operating T...

Страница 14: ...rest Lindsay Dealer visit www zimmatic com or write Service Department Lindsay Manufacturing LLC 214 East Second Street Lindsay NE USA 68644 Zimmatic Customer Service call 800 829 5300 LAN lines requi...

Страница 15: ...P N 1604010 Rev D ECN 35207 1 5 Multi Control Operation Manual Section 1 Specifications and Compliance Panels Panel ID Locations Micro Controller Panel...

Страница 16: ...P N 1604010 Rev D ECN 35207 1 6 Multi Control Operation Manual Section 1 Specifications and Compliance Expansion Panel...

Страница 17: ...P N 1604010 Rev D ECN 35207 1 7 Multi Control Operation Manual Section 1 Specifications and Compliance Wireless Switch...

Страница 18: ...P N 1604010 Rev D ECN 35207 1 8 Multi Control Operation Manual Section 1 Specifications and Compliance...

Страница 19: ...r and chemical delivery sensor monitor ing temperature protection and system awareness The Micro Control allows for establishing multiple irrigation plans and remote control through FieldNET Lindsay s...

Страница 20: ...nter will illuminate with the proper status color when the mode button is pressed see the status center diagram shown later in this section The following diagram shows the sequence for stepping though...

Страница 21: ...tor LED s Alert Displays any communication errors Operation Mode As describe previously this will indicate which mode the Multi Control is operating in Status Indicates the system status FieldNET Indi...

Страница 22: ...P N 1604010 Rev D ECN 35207 2 4 Multi Control Operation Manual Section 2 Operation...

Страница 23: ...ture Shutdown 1 High Shutdown due to system temperature being lower than the allowable limit High Injector Flow Shutdown 1 High Shutdown due to flow through an injector exceeding the allowable limit L...

Страница 24: ...nearing the minimum limit High Temperature Warning 2 Medium Temperature is nearing the maximum limit Low Temperature Warning 2 Medium Temperature is nearing the minimum limit High Injector Flow Warnin...

Страница 25: ...ter flush cycle Filter Flush Cycle Running 3 Low The filter flush cycle is running Powered Off Normal 3 Low The Multi Control is properly powered off Temperature Protection Plan Running 3 Low A temper...

Страница 26: ...P N 1604010 Rev D ECN 35207 3 4 Multi Control Operation Manual Section 3 Service...

Страница 27: ...ion Manual Revisions 9Date16 ECN Published ECN Description 8 22 14 32745 32745 Reformatted Manual 5 9 16 34225 34225 Updated Compliance Specifications and Certificate 6 26 2017 35207 35207 Updated Saf...

Страница 28: ...P N 1604010 Multi Control Operation Manual Revisions...

Отзывы: