Table of defects:
MALFUNCTION
CAUSE
REMOVAL
beverage does not flow
keg tapped incorrectly
check that the keg coupler lever is pushed
down
the keg is not pressurised
pressurise the keg
compensator is closed
move the compensator lever
beverage cooled
insufficiently
incorrect thermostat setting
turn the thermostat knob
to the right towards number 7
poor air circulation
check the cleanliness of condenser plates
device overheats
place the device in a colder environment
tap jerks, drink sprays out
pressure too high
reduce delivery medium supply, reduce
pressure in the
keg
beer foams excessively
reduce beverage temperature - turn
the thermostat knob to the right,
Speed fiting leaking
hose
incorrectly
inserted
pull out the hose, check that the end of the
hose is flat (not at an angle), level off with
a knife if needed
scratches on the hose
pull out the hose and shorten by ca. 2 cm
NOTE:
If the defect persists even after the above steps are taken, contact a service
centre.
Содержание Green Line AS-110-US
Страница 2: ...2...
Страница 15: ...15 14 Interconnecting beverege tubing The figure shows a model example of connection...
Страница 19: ...19...
Страница 20: ...20 2 Keg untapping...
Страница 21: ...21 A system keg coupler...
Страница 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...
Страница 23: ...23...
Страница 24: ...24 2 Keg untapping...
Страница 28: ...28 Warning Disconnect the device from power before cleaning the condenser 1 2 3...
Страница 29: ...29 4 5 6 7...
Страница 34: ...34 27 Wiring diagram...
Страница 35: ...35 28 Cooling diagram...
Страница 36: ...36...