![LINDR 3893 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/lindr/3893/3893_instruction-manual_1919622015.webp)
SANIT
ATION OF FL
OW
-THR
OUGH CONT
AC
T COOLING
15
8. TAP DISASSEMBLY :
9. D-RING REPLACEMENT:
D-Ring
figure
15 A
figure
15 B
• Using a flat-blade screwdriver, unscrew the
screw (1.) to the left and remove the spring
(2.).
• Unscrew the nut on the tap lever and remo-
ve it upwards (3.).
• Unscrew the nut on the compensator and
remove the compensator (4.).
• Remove the inner part of the compensator
(5.). Remove the piston (6.).
• Loosen the piston nut (1.) with a size 12
wrench.
• Remove the spring (2.) and the piston
washer (3).
• Replace D-ring (4.) if worn or damaged.
• After replacement, assemble everything in
reverse order.
10. SANITATION ADAPTER:
S-type
A-type
M-type
• Sanitizing adapters are used for water pres-
sure cleaning. They have a brass body and a
1/2“ hose is attached to them.
Содержание 3893
Страница 2: ...2 ...
Страница 10: ...10 16 TECHNICKÝ LIST EFFEKTOMAT AFL ...
Страница 19: ...SANITATION OF FLOW THROUGH CONTACT COOLING 19 ...
Страница 20: ......