background image

User guideline NORTEC sonic

NRSB-09

Issued by: PM Floor Division 

10.6.09 

Page 4 of 6 

Rev.00

NRBS-09

NORTEC sonic with visible perforation

Place the lifting device on one side in one of the

ventilation holes in the middle of the outer edge

of the panel, hold the panel with your hands, lay it

with one side on two pedestals and push it to the

neighbouring panel.

Lower the panel with the lifting device.

Attention

Never put your fingers in the gap between the panels with the opening and closing of the
system – danger of injury! (Illustration B)

Do never try to take up panels with unsuited tools like a screwdriver or a chisel (Illustration
C), as the panel edges can be damaged irreparably by this.

Detach the lifting device immediately after the use.

Do not put taken out panels down on the panel edge.

Illustration B

Illustration C

Basically: 

 

- Remove dirt of pedestal head.
- Test if the gasket and eventually the stringers rest on the pedestal 

head properly.

 

 

 

 

- Check the installation direction of the covering.

Taken out panels shall be put back in their original positions and shall not be turned around
into a different position. Special attention has to be paid to the covering direction with

Содержание NORTEC

Страница 1: ...the climate beyond the specified tolerances will cause a swelling or shrinking of the floor system according to the material used 2 Opening and closing of the floor system If panels are taken out of the floor area or channels for later installation works or similar it has to be paid attention to that this is done like it is shown in the following illustration Free standing pedestals which are not ...

Страница 2: ...s The raised floor panels may only be lifted with a suited lifting device The system may only be opened or closed by qualified personnel Illustration A 2 1 Taking out of a panel NORTEC sonic with covered perforation textile covering Place the spike lifter in the centre of the panel edge with a short distance to the edge of approximately 5 cm and lift the panel slightly to loosen it and then remove...

Страница 3: ...ion hole at the middle of the outer edge on the left and right side of the panel and lift it vertically 2 2 Inserting of panel NORTEC sonic with covered perforation textile covering Place the lifting device on one side hold the panel with your hands lay it with one side on two pedestals and push it to the neighbouring panel Lower the panel with the lifting device If with the use of a velour coveri...

Страница 4: ...ing of the system danger of injury Illustration B Do never try to take up panels with unsuited tools like a screwdriver or a chisel Illustration C as the panel edges can be damaged irreparably by this Detach the lifting device immediately after the use Do not put taken out panels down on the panel edge Illustration B Illustration C Basically Remove dirt of pedestal head Test if the gasket and even...

Страница 5: ... again assured 4 Cable installation Do not draw in cables over the edge of the floor system or a panel Do not pull off or damage pedestals through overstraining with the installation of cables in the cavity Good idea Lay cables in from the roll 5 Protective measures 5 1 Extraordinary loading The floor has to be covered with planks chipboards or steel plates with the transport of heavy loads The fl...

Страница 6: ...visible perforation The floor system should only be cleaned and maintained slightly damp The cleaning devices like a mop or similar may not release mopping water resp care emulsion into the perforation holes The cleaning water can penetrate into the perforation with the use of wet cleaning machines This has to be avoided absolutely Generally an overwatering too much spraying with cleaning agents a...