Design and function 

MMA welding 

 

099-000235-55801 

06.11.2017

 

25 

 

5.2.2.1 

Connecting the shielding gas supply 

•  Place the shielding gas cylinder into the relevant cylinder bracket. 

•  Secure the shielding gas cylinder using a securing chain. 

 

Figure 5-10 

 

Item  Symbol 

Description

 0

 

 

Pressure regulator 

 

Shielding gas cylinder 

 

Output side of the pressure regulator 

 

Cylinder valve 

 

• 

Before connecting the pressure regulator to the gas cylinder, open the cylinder valve briefly to blow out 

any dirt.

 

•  Tighten the pressure regulator screw connection on the gas bottle valve to be gas-tight. 

•  Screw gas hose connection crown nut onto the output side of the pressure regulator. 

 

 

Figure 5-11 

 

Item  Symbol 

Description

 0

 

 

Connecting nipple G¼, shielding gas connection 

 

•  Connect crown nut of the shielding gas line to the G¼“ connecting nipple. 

 

Содержание TPL 300 puls AC/DC

Страница 1: ...Operating instructions EN Power source TPL 300 puls DC TPL 300 puls AC DC 099 000235 55801 Observe additional system documents 06 11 2017...

Страница 2: ...use please contact your sales partner Liability relating to the operation of this equipment is restricted solely to the function of the equipment No other form of liability regardless of type shall b...

Страница 3: ...1 Transport and installation 17 5 1 1 Ambient conditions 17 5 1 1 1 In operation 17 5 1 1 2 Transport and storage 17 5 1 2 Machine cooling 18 5 1 3 Workpiece lead general 18 5 1 4 Adjusting the lengt...

Страница 4: ...als 30 6 3 1 Daily maintenance tasks 30 6 3 2 Monthly maintenance tasks 30 6 3 3 Annual test inspection and testing during operation 31 6 4 Disposing of equipment 31 7 Rectifying faults 32 7 1 Checkli...

Страница 5: ...erved to prevent serious and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning symbol The hazard is also highlighted using a symbol in the page margin...

Страница 6: ...off machine Release Switch on machine Press and keep pressed Switch Wrong Turn Correct Numerical value adjustable Menu entry Signal light lights up in green Navigating the menu Signal light flashes gr...

Страница 7: ...of a welding system Figure 2 1 Item Documentation A 1 Options conversion instructions A 2 Power source A 3 Cooling unit voltage converter tool box etc A 4 Transport cart A 5 Welding torch A 6 Remote c...

Страница 8: ...erconnect welding machines with pole reversing switch PWS series or machines for AC welding since a minor error in operation can cause the welding voltages to be combined which is not permitted Risk o...

Страница 9: ...fire extinguishers are available in the working area Thoroughly remove any residue of flammable materials from the workpiece prior to starting to weld Only further process workpieces after they have c...

Страница 10: ...control signal and telecommunication lines Radios and televisions Computers and other control systems Safety equipment The health of neighbouring persons especially if they have a pacemaker or wear a...

Страница 11: ...s per IEC 60974 4 The manufacturer s warranty becomes void if non genuine parts are used Only use system components and options power sources welding torches electrode holders remote controls spare pa...

Страница 12: ...sport the machine on level solid ground Secure add on parts using suitable equipment Risk of accidents due to incorrectly installed leads Incorrectly installed leads mains control and welding leads or...

Страница 13: ...ich also apply 3 2 1 Warranty The statutory warranty period is one year from the date of purchase By registering the product you extend the statutory warranty period to three years and in the case of...

Страница 14: ...comes null and void in the event of unauthorised interference Appoint only skilled persons for repair work trained service personnel Original copies of the circuit diagrams are enclosed with the unit...

Страница 15: ...socket welding torch control cable see 5 2 1 1 chapter 4 Connection socket welding current MMA Electrode holder or workpiece lead connection TIG Connection for workpiece lead 5 Cooling air inlet 6 Co...

Страница 16: ...socket Cooling unit control lead 3 4 pole connection socket Cooling unit voltage supply 4 Cooling air outlet 5 Machine feet 6 Mains connection cable see 5 1 7 chapter 7 G connecting nipple Shielding g...

Страница 17: ...handles straps or brackets are suitable for transport by hand only The machine must not be suspended or lifted using a crane 5 1 1 Ambient conditions T he machine must not be operated in the open air...

Страница 18: ...ding current plugs machine connections are not locked or if the workpiece connection is contaminated paint corrosion these connections and leads can heat up and cause burns when touched Check welding...

Страница 19: ...le connection socket Cooling unit control lead 2 4 pole connection socket Cooling unit voltage supply 3 Cooling module Insert and lock the 8 pole control lead plug on the cooling unit into the 8 pole...

Страница 20: ...rces with HF igniter TIG for as long as possible in parallel with a distance of 20 cm to avoid HF sparkover Always keep a distance of at least 20 cm to leads of other power sources to avoid interferen...

Страница 21: ...fire Check that all welding current connections are firmly secured and electrical connections are in perfect condition Set up attach or suspend all conductive power source components such as casing t...

Страница 22: ...hecked by an electrician on a regular basis When operating the generator always ensure it is earthed as stipulated in the operating instructions The network created must be suitable for operating mach...

Страница 23: ...ction Insert the welding current plug on the welding torch into the welding current connection socket and lock by turning to the right Remove yellow protective cap on G connecting nipple Screw welding...

Страница 24: ...lding machine WARNING Risk of injury due to improper handling of shielding gas cylinders Improper handling and insufficient securing of shielding gas cylinders can cause serious injuries Observe the i...

Страница 25: ...cylinder 3 Output side of the pressure regulator 4 Cylinder valve Before connecting the pressure regulator to the gas cylinder open the cylinder valve briefly to blow out any dirt Tighten the pressure...

Страница 26: ...ction nipple protects against electrical voltage and dirt Figure 5 12 Item Symbol Description 0 1 Electrode holder 2 Connection socket welding current Workpiece lead or electrode holder connection 3 W...

Страница 27: ...chine The connection must only be made using the cables supplied do not use any additional extension cables 5 5 Interfaces for automation Damage to the machine due to improper connection Unsuitable co...

Страница 28: ...ification for main current 0 10V 0V Imin 10V Imax 5 D Input Control value specification for secondary current 0 10V 0V Imin 10V Imax 6 J U Output Reference 0V 7 K Output Power supply 15V max 75mA 8 V...

Страница 29: ...der warranty is void In all service matters always consult the dealer who supplied the machine Return deliveries of defective equipment subject to warranty may only be made through your dealer When re...

Страница 30: ...Gas tubes and their switching equipment solenoid valve Gas cylinder securing elements Check correct mounting of the wire spool Check that all screw and plug connections and replaceable parts are secu...

Страница 31: ...ispose of in household waste Observe the local regulations regarding disposal According to European provisions Directive 2012 19 EU on Waste of Electrical and Electronic Equipment used electric and el...

Страница 32: ...hose packages Reset automatic cutout of the coolant pump by activating Air in the coolant circuit Vent coolant circuit see 7 2 chapter Several parameters cannot be set machines with access block Entr...

Страница 33: ...in the tungsten electrode due to contact with filler material or workpiece Regrind or replace the tungsten electrode Incompatible parameter settings Check settings and correct if necessary Pore format...

Страница 34: ...nt circuit Coolant tank and quick connect coupling of coolant supply and return are only fitted in machines with water cooling To vent the cooling system always use the blue coolant connection which i...

Страница 35: ...min welding 4 min pause Open circuit voltage 63 V Mains voltage tolerances 3 x 400 V 25 to 20 Frequency 50 60 Hz Mains fuse safety fuse slow blow 3 x 16 A Mains connection lead H07RN F4G2 5 Max connec...

Страница 36: ...s voltage tolerances 3 x 400 V 25 to 20 Frequency 50 60 Hz Mains fuse safety fuse slow blow 3 x 16 A Mains connection lead H07RN F4G2 5 Max connected load 11 7 kVA 17 kVA Recommended generator rating...

Отзывы: