Design and function
Transport and installation
099-008600-55801
29.08.2017
13
5.1.1
Connecting the supply lines
Control and supply lead to the welding machine
The cooling module and welding machine are connected using two leads.
• Insert the control lead plug on the welding machine.
• Insert the power supply lead plug on the welding machine.
5.2
Transport and installation
WARNING
Risk of accident due to improper transport of machines that must not be lifted!
Do not lift or suspend the machine! The machine can drop and cause injuries! The handles, straps or
brackets are suitable for transport by hand only!
• The machine must not be suspended or lifted using a crane.
5.2.1
Machine cooling
Insufficient ventilation results in a reduction in performance and equipment damage.
• Observe the ambient conditions!
• Keep the cooling air inlet and outlet clear!
• Observe the minimum distance of 0.5 m from obstacles!
5.2.2
Ambient conditions
T he machine must not be operated in the open air and must only be set up and operated on a suitable, stable
and level base!
• The operator must ensure that the ground is non-slip and level, and provide sufficient lighting for the place
of work.
• Safe operation of the machine must be guaranteed at all times.
Unusually high quantities of dust, acid, corrosive gases or substances may damage the equipment.
• Avoid high volumes of smoke, vapour, oil vapour and grinding dust!
• Avoid ambient air containing salt (sea air)!
5.2.2.1
In operation
Temperature range of the ambient air:
• -25 °C to +40 °C
Relative air humidity:
• Up to 50% at 40 °C
• Up to 90% at 20 °C
5.2.2.2
Transport and storage
Storage in an enclosed space, temperature range of the ambient air:
• -30 °C to +70 °C
Relative air humidity
• Up to 90% at 20 °C