Lindab SRF Скачать руководство пользователя страница 2

 

 

 

lindab  

|

  we simplify construction 

M A I N T E N A N C E  

 

Before service, maintenance or repair begins, the 
fan  must  be  tension  free  and  the  impeller  must 
have stopped. 

 

Consider the weight of the fan when removing or 
opening larger fans to avoid jamming and contu-
sions. 

 

The fan must be cleaned when needed, at least once 
per year to maintain the capacity and to avoid unba-
lance which may cause unnecessary damages on the 
bearings. 

 

The fan bearings are maintenance-free and should 
be renewed only when necessary. 

 

When cleaning the fan, high-pressure cleaning or 
strong dissolvent must not be used. 

 

Cleaning  should  be  done  without  dislodging  or 
damaging the impeller. 

 

Make sure that there is no noise from the fan. 

 

F A U L T   D E T E C T I O N  

1.

 

Make sure that there is tension to the fan. 

2.

 

Cut the tension and verify that the impeller is not 
blocked. 

3.

 

Check the thermo-contact/motor protector. If it is 
disconnected  the  cause  of  overheating  must  be 
taken  care  of,  not  to  be  repeated.  To  restore  the 
manual thermo-protector the tension will be cut for 
a couple of minutes. Larger motors than 1,6 A may 
have manual resetting on the motor. If it has auto-
matic  thermo-protector  the  resetting  will  be  done 
automatically when the motor is cold. 

4.

 

Make sure that the capacitor is connected, (single 
phase only) according to the wiring diagram. 

5.

 

If the fan still does not work, the first thing to do 
is to change the capacitor. 

6.

 

If nothing of this works, contact your fan supplier. 

7.

 

If the fan is returned to the supplier, it must be 
cleaned,  the  motor  cable  undamaged  and  a 
detailed nonconformity report enclosed.

Отзывы: