OPERATING MANUAL

STEP 1: ASSEMBLY

Assembling the StaticSure is fast and easy.

  

+

  Plug each of the two (2) cables into opposite ends of the StaticSure device

      and tighten them securely.

  

+

  Either cable can be plugged into both sides of the device - there is no right or

       wrong side.

  

+

  Ensure that the ridge (FIGURE 1) on the device connector aligns with the groove

      in the cable connector prior to pushing and tightening.

HOW TO USE THE StaticSure

STEP 2: SET UP

a) Bonding Applications:

 Bonding refers to creating a link between two objects using

a conductive material (e.g. a wire) in order to ensure that they remain at the same
electrical potential, thus reducing risk of static discharge between the objects.

  

+

  The device can be attached to the objects that you wish to bond using either a

      lug terminal which can be bolted to an object, or a hand clamp.

  

+

  Once the cables have been assembled per STEP 1, you should attach one side

      of the StaticSure assembly to one of the objects you wish to bond using either a
      clamp or a lug termination.

  

+

  You must ensure that metal to metal contact is made by either the jaws of the

      clamp or the lug terminal in order to establish proper continuity.

  +

  If the red light is flashing after attaching this side, you do not have good metal to

      metal contact and should reattach this side until the light goes off.

  +

  The other side of the assembly is now ready to be attached to the second object

      that you wish to bond (FIGURE 2), 

but first the device should be tested

.

  

+

  

See STEP 3 for testing instructions.

HOW TO USE THE StaticSure

4

    LIND EQUIPMENT LTD.    T: 877.475.LIND    www.lindequipment.net

LIND EQUIPMENT LTD.    T: 877.475.LIND    www.lindequipment.net    

5

FIGURE 1

FIGURE 2

Align groove on connector

with pin on receptacle

Содержание Static Sure

Страница 1: ...NTURIAN DRIVE MARKHAM ON CA L3R 8C4 300 INTERNATIONAL DRIVE SUITE 100 WILLIAMSVILLE NY US 14221 T 877 475 LIND 5463 F 877 475 2030 info lindequipment net www lindequipment net PORTABLE STATIC MONITORING SYSTEM OPERATING MANUAL ...

Страница 2: ...being achieved The device can be used to either provide the static electricity with a path to a known ground point such as a ground bus or to provide a bond between two objects that allows the electrical potential to equalize thus reducing the risk of static discharge between the two objects To ensure that there is a proper bond the StaticSure tests whether resistance in the circuit is below the i...

Страница 3: ...sing either a lug terminal which can be bolted to an object or a hand clamp Once the cables have been assembled per STEP 1 you should attach one side of the StaticSure assembly to one of the objects you wish to bond using either a clamp or a lug termination You must ensure that metal to metal contact is made by either the jaws of the clamp or the lug terminal in order to establish proper continuit...

Страница 4: ...hat you wish to ground FIGURE 3 but first the device should be tested See STEP 3 for testing instructions HOW TO USE THE StaticSure STEP 3 TESTING Testing of the device is simple and should be done before each usage Once the device has been assembled and set up properly you can test it by simply opening the clamp on the unattached side simulating a break in the continuity If the device is working ...

Страница 5: ...ave a safe connection and can proceed with your operation If the warning light starts blinking following the connection take the following actions 1 Check the assembly to ensure that all cables are properly fastened per instructions in STEPS 1 and 2 2 Ensure that there is proper metal to metal contact on the attached end 3 Ensure that the item you are attempting to bond is electrically conductive ...

Страница 6: ...F G Temperature Code T4 Ambient Temperature Ta 40 C Ta 50 C 40 F Ta 122 F Resistance Setting 10 Ohms Life Expectancy The battery is designed to last for approximately 3 4 years based on average industry usage parameters Environmental Rating IP65 MAINTENANCE While the LE600i StaticSure can be used as a portable device the option of mounting the unit is also offered The pair of U clamps provided in ...

Страница 7: ...cord with lugs Assembly containing the LE600i 2 18 2 SOW straight cord with GAT PIP clamp 20 18 2 SOW coiled cord with lugs Assembly containing the LE600i 2 18 2 SOW straight cord with REB IP clamp 20 18 2 SOW coiled cord with lugs Replacement cable assembly 2 18 2 SOW straight cord with lugs and connector Replacement cable assembly 20 18 2 SOW coiled cord with lugs and connector NOTE Other hand c...

Отзывы: