11
Ékszíjas meghajtású, olajkenésű, dugatt
LINCOS Slovenia
STD-3550
Two Post Lift - Electrical Release
•
Check hydraulic fluid level as follow: let the trolleys go up completely and in
case they do not reach maximum height, add oil.
•
Check and tighten bolts, nuts and screws.
5.3 MONTHLY MAINTENANCE
•
Check the tightening of screws.
•
Check the hydraulic system seal and tighten the loose unions, if necessary.
•
Check the greasing and wear condition of pins, rollers, bushes, of trolley
structure as well as arms and relevant extensions, if necessary, replace the
damaged parts by original spare parts.
5.4 YEARLY MAINTENANCE
•
Empty the tank and check the conditions of the hydraulic fluid. Clear the oil
filter.
If the above maintenance operations are carried out, there will be an advantage
for the user, who will find the equipment in perfect condition each time he
restarts work.
6 TROUBLE SHOOTING
MOTOR DOES NOT RUN
A) Breaker or fuse blown. Replace it.
B) Motor thermal overload tripped. Wait for overload to cool.
C) Faulty wrong connections. Call electrician for checking.
D) Defective up button. Call electrician for checking.
MOTOR RUNS BUT WILL NOT RAISE
A) A piece of trash is under check valve. Push handle down and push the up
button at the same time. Hold for 10-15 seconds, which should flush the
system.
B) Check the clearance between the plunger valves of the lowering handle.
C) Remove the check valve cover and clear the ball and seat.
D) Oil level too low. Oil level should be just under the vent cap port when the lift is
down.
OIL BLOWS OUT BREATHER OF POWER UNIT
A) Oil reservoir overfilled.
B) Lift lowered too quickly while under a heavy load.
C) Bad capacitor. Call electrician for checking.
D) Low voltage call electrician for checking.
E) Lift overloaded.
MOTOR HUMS AND WILL NOT RUN
A) Impeller fan cover is dented. Take off and straighten.
B) Faulty wiring. Call electrician for checking.