E-2
TROUBLESHOOTING
E-2
TOMAHAWK™ 625
ERROR SIGNALS
Alarm
(abnormal condition)
Undervoltage
Overvoltage signal
Underpressure
PIP (Parts In Place)
Thermal Shutdown
OCV
Overvoltage shutdown
RED
LED
OFF
Blink
Blink
ON
OFF
Blink
OFF
YELLOW
LED
Blink
OFF
OFF
ON
ON
Blink
Blink
Blinking fre-
quency (Hz)
1
4
1
steady on
steady on
1
3
Reset mode
Autoreset with hysteresis.
Autoreset with hysteresis.
Autoreset.
Autoreset after 5sec.
Autoreset after cooling time.
Autoreset after trigger release.
Autoreset after 2min of cooling
time.
NOTE
Error and shutdown when the input voltage is less than
187Vac.
Error when the input voltage is greater than 270Vac.
Error and shutdown when the input air pressure is low.
Error and shutdown when the retaining cap is not
attached properly.
Normal thermal response due to overheating.
Safe Mode - if trigger is pulled while turning the machine
on, or attaching consumables with the trigger pulled.
This shutdown occurs if the machine cuts for more than
20sec in overvoltage condition (Vin>270Vac).
Signal
(normal operation)
Power on
Inverter on
GREEN
LED
ON
ON
RED
LED
OFF
ON
Blinking fre-
quency (Hz)
steady on
steady on
Reset mode
Always on when the machine is
energized.
When the torch trigger is released.
NOTE
Normal operating condition when trigger is off.
Normal operating condition when trigger is pulled.
Содержание TOMAHAWK 625