A-1
INSTALLATION
TCV400
A-1
TECHNICAL SPECIFICATIONS – TCV400
Idle Current - Amps
3.2A (380V 50 Hz)
MAX OCV:
46
Input kVA
29.6 @ 400A 34V (50 Hz)
Power Factor
.65 @ 400A 34V (50 Hz)
Rated Current
45A @ 400A 34V (380V/50 Hz)
Efficiency
70% @ 400A 34V (50 Hz)
Idle Power
1.0 KW (50 Hz)
MISC. INFORMATION
RATED INPUTS
RATED OUTPUTS
Height
Width
Depth
Weight
27.5 in.
23.28 in.
32.0 in.
383 lbs
699 mm
591 mm
813 mm
(174 kg)
PHYSICAL DIMENSIONS
Duty Cycle
50%
60%
100%
Standard Voltage
50/60 Hz
200/230/400/460
Volts
39V
Amps
500A
450A
400A
Operating Temperature -40°C to +40°C
Output Range
60A 17V (Minimum)
500A 39V (Maximum)
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT
VOLTAGE /
FREQUENCY
200
230
400
460
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
1
125 Amp
125 Amp
70 Amp
60 Amp
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
6 (14)
6 (14)
8 (8.4)
10 (5.3)
TYPE 75°C
COPPER WIRE
IN CONDUIT
*
AWG(IEC-MM
2
) SIZES
30°C (86°F) Ambient
3 (27)
4 (21)
8 (8.4)
8 (8.4)
INPUT AMPERE
RATING ON
NAMEPLATE
**
78
75
43
39
HERTZ
50/60
* Ambient temperature of 40°C (104°F).
** At rated output of 400A, 100% duty cycle.