3
Erection and Assembly
4
Operating Instructions
3.1
Erection of Pump
Requirements on the place of installation
· protected from dust and dirt
· safe against atmospheric influences (note the protection type
of the electric motor)
· enough space for opening the reservoir cover and executing
the maintenance works (the space required depends on the
pump size)
· even, solid and vibration-free place of
erection
3.2
Electrical Connection
All electrical work should be undertaken only by qualified per-
sonnel.
Connect the low level control acc. to terminal diagram, item
2.5. Observe the enclosed circuit diagrams.
4.1
Commissioning
The pump is filled with lubricant in the factory and vented. The
lubricant remains in the pump which is protected by a plastic
bag on delivery and for storage. After the plastic bag has been
removed, the pump can be put into a full lubricant drum and
must not be vented.
The pump should be put into operati-
on only after it has been placed into a
full lubricant drum. When changing
the drum, pay a great attention that no
dust or dirt enters the drum. The
drum cover must evenly lie on the
drum edge.
The driving air must be free from condensate and impurities.
For the air treatment, use a air maintenance unit consisting of
air filter, pressure regulator and lubricator.
Adjust the pressure regulator of the air maintenance unit to 5
bar.
Do not adjust the air regulator over 7
bar. All system components (tubes,
hoses, tube fittings, etc.) must be de-
signed for the maximum system pres-
sure.
Overpressure safety valve
In spray systems with controlled nozzles the lubricant line is
equipped with a safety valve which is set to a pressure of 120
bar (integrated in the stand with winch)
Lubricant filter
It is recommended to use a lubricant filter to avoid failures
which might be caused by impurities (in spray systems, a filter
is already installed on the mounting plate).