background image

Subject to modifications

User Manual

Technical Description

2.2A-10003-B06

LINCOLN GmbH & Co. KG • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Page 35 of 40

Applications 

Multi-line and Progressive System 

 

4025a95 

Fig. 46 

Multi-line pump expanded by a progressive metering device  

 

Extensibilities of Multi-line and Progressive Systems 

 

1207a95 

Fig. 47 

Two-line system expanded by a progressive metering 
device 

‚

 

Progressive metering devices can be used in two-line or 
single-line centralized lubrication systems in order to in-
crease the number of outlets of multi-line pumps or to 
subdivide the single metering devices and measuring 
valves (fig. 46 to 50) also as secondary metering devices 
in large and small oil circulating systems.

 

 

1206a95 

Fig. 48 

Single-line system expanded by a progressive metering 
device 

 

Содержание Quicklub SSV D

Страница 1: ...iption 2 2A 10003 B06 LINCOLN GmbH Co KG Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Quicklub Progressive Metering Devices for Grease and Oil Model SSV D Planning and Layout of...

Страница 2: ...7 33 0 Fax 49 6227 33 259 All rights reserved Any duplication of this User Manual in its entirety or in part by whatever means is prohibited without the prior consent in writing of Lincoln GmbH CO KG...

Страница 3: ...Printed Circuit Board 236 13870 1 Variant M 08 M 15 1 Printed Circuit Board 236 13870 1 Variant M 16 M 23 1 Installation Instructions Parts Catalog 1 The model designation of the printed circuit board...

Страница 4: ...sequence of contents Procedural instruction User s Responsibility To ensure the safe operation of the unit the user is responsi ble for the following 1 The pump system shall be operated only for the i...

Страница 5: ...must be sub ject to prior consultation with the manufacturer of the lu brication system Use only original Lincoln spare parts see Parts Catalog or the parts approved by Lincoln Regulations for Preven...

Страница 6: ...Inlet fittings Metering devices Inlet tube fittings straight and 90 6001a02 IMPORTANT For the inlet fittings use only tube fittings with reinforced collet 1a fig 2 and sealing ring 1b at the thread 1a...

Страница 7: ...ard collet knurled collet and to the inlet fittings towards the lubrication point knurled collet 6001a02 NOTE Special cases such as applications for construction machines or agricultural ma chines req...

Страница 8: ...d in the chapter Technical Data when installing the parts and operating the device Installing the threaded sleeves and hose studs on the high pressure hose Screw threaded sleeve item 1 Fig 7 countercl...

Страница 9: ...respective pressure relief valve 6512b05 Fig 10 Metering and control piston assy 1 Metering piston 2 Control piston P Input pressure D Larger metering piston diameter d Smaller control piston diameter...

Страница 10: ...ible from both sides due to three bore rows see pos I to III Fig 11 I Control piston level behind closure plugs II Metering piston level medium level behind metering screws III Outlet level behind clo...

Страница 11: ...d of control piston B and metering piston B Due to the bigger diameter the lubricant pressure P first moves metering piston B black arrow to the left and then supplies the enclosed lubricant on the le...

Страница 12: ...d of control piston C and metering piston C Due to the larger diameter the lubricant pressure P first moves metering piston C black arrow to the left and then supplies the enclosed lubricant on the le...

Страница 13: ...d of control piston A and metering piston A Due to the larger diameter lubricant pressure P first moves the metering piston A black arrow to the left and then supplies the enclosed lubricant on the le...

Страница 14: ...control piston B and metering piston B Due to the larger diameter lubricant pressure P first moves the metering piston B black arrow to the right and then supplies the enclosed lubricant on the right...

Страница 15: ...control piston C and metering piston C Due to the larger diameter the lubricant pressure P first moves metering piston C black arrow to the right and then supplies the enclosed lubricant on the right...

Страница 16: ...arger diameter lubricant pressure P first moves the metering piston A black arrow to the right and then supplies the enclosed lubricant on the right side of metering piston A to outlet 5 V1 Phase 12 W...

Страница 17: ...d see broken lined junction channel between outlet 2 and 1 One outlet of one side of the metering device is closed in order to be able to use the double lubricant quantity on the other side Outlet V V...

Страница 18: ...metering device If any metering device fails due to the functional interlink also the main metering device blocks This means the complete progressive system is stopped A pressure relief valve E pressu...

Страница 19: ...dered sepa rately for each lubrication system Refer to the Parts Catalog The pre assembled metering devices have the designa tion SSV D 6 N to 22 N they are available for SSV D 6 8 10 12 to 22 They mu...

Страница 20: ...ns of metering screws see page 19 you may also increase the output by clos ing outlet bores Install an outlet fitting assembly pos 5 M 10 x 1 in each outlet bore to be used Never remove closure plug p...

Страница 21: ...device with knurled collet 6001a02 NOTE In the case of construction machines or agricultural machines use high pressure hoses for the lubricant feed lines In this case secondary metering devices see...

Страница 22: ...with the application Note the application possibilities for the metering device monitoring Protect the pump by means of an adequate pressure relief valve see Parts Catalogs 2 Determining the number o...

Страница 23: ...corre sponding metering possibilities These may be lubricant metering devices SSV or adjustable metering devices SSV D 5 Additional increase of lubricant quantities with SSV D metering devices 6508b05...

Страница 24: ...location of the required metering quantities of the SSV D 6514b05 Fig 35 Allocate metering device outlets to the lube points Allocate equal lubricant quantities to the corresponding metering screw s o...

Страница 25: ...metering device to each secondary metering device UV If possible supply the same lubricant quantities to similar lubrication points Check whether one or several lube points require larger lubricant qu...

Страница 26: ...at least once every day at the latest on the next day see step 12 page 27 Avoid too much lubricant per day and per lubrication point excessive lubrication Avoid too little lubricant per day and per lu...

Страница 27: ...system select the time for the biggest secondary metering device as a function of the main metering device used If it is not possible to adjust a time parameter within the programmable scale select t...

Страница 28: ...ntly this superstructure or auxiliary unit can be supplied from a specially installed pump element 6001a02 IMPORTANT Each pump element must be equipped with a pressure relief valve 1022b03 Fig 41 Usin...

Страница 29: ...ould be made only via 2 steps of metering devices i e main metering device secondary metering device lubrication point 1023b96 A main metering device B secondary metering device Fig 42 Maximum line le...

Страница 30: ...bar m Maximum pressure loss through each SSV D 6 to SSV D 22 NLGI 0 20 bar 15 bar 10 bar NLGI 1 25 bar 20 bar 15 bar NLGI 2 30 bar 25 bar 20 bar Tab 1 Maximum pressure loss 6001a02 NOTE The data rela...

Страница 31: ...of the signal lamp if any or LED display 6001a02 IMPORTANT If there is a blockage in the downstream system the main lines are under pressure In such a case it is difficult to detach the push in type c...

Страница 32: ...not correct Check the lubricant metering acc to the lubrication chart Setting of the pause time or operating time incorrect Check the time setting Fault Excessive or poor lubrication of the lubricatio...

Страница 33: ...cation point Lines Main Line NW 4 1 x 2 3 mm Min bursting pressure in connection with hose clamp screwed 600 bar Min bending radius 35 mm Min temperature 40 C Pressure plastic tube 6 x 1 5 mm Min bend...

Страница 34: ...bH Co KG Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Technical Data continuation Dimensions Metering device model SSV D 6 to SSV D 22 2012b05 Fig 45 Metering device model SSV D...

Страница 35: ...s of Multi line and Progressive Systems 1207a95 Fig 47 Two line system expanded by a progressive metering device Progressive metering devices can be used in two line or single line centralized lubrica...

Страница 36: ...machine to one or more central lubrication points as shown in fig 49 which illustrates this basic feature Extensibilities of the lubrication system 4024b95 Fig 50 Possible pump connections 1 Hand oper...

Страница 37: ...3 graphite that are transportable in lubrication systems only conditionally The lubricants released by us have not been tested with re gard to their long term behavior 6001a02 IMPORTANT The manufactur...

Страница 38: ...t 2 EP Li 20 C DEA Glissando 20 Li 12 OH stearat 15 to 10 C ESSO Ronex Extra Duty 2 Li complex 5 C ESSO Ronex MP2 Li complex 5 C ESSO Beacon EP2 Li 5 C ESSO Cazar K2 Ca 15 C FIAT LUBRIFICANTI Comar 2...

Страница 39: ...t Manufacturer Designation Thickener min delivery temperature ARAL EURAL Grease EPF 2 Al complex 5 C BREMER LEGUIL Rivolta F L G 4 2 Al complex 20 C ELKALUB GLS 364 organic thickener 10 C ELKALUB GLS...

Страница 40: ...ne Lincoln Way St Louis MO 63120 1578 USA Phone 1 314 679 4200 Fax 1 800 424 5359 Lincoln GmbH Co KG Heinrich Hertz Stra e 2 8 69190 Walldorf Germany Tel 49 6227 33 0 Fax 49 6227 33 259 Lincoln Indust...