Spare part assy for housing
consisting of items 3, 4, 6 - 15
Designation
Part no.
Housing assy for PMA2-...-1
551-32568-1
Housing assy for PMA2-...-2
551-32569-1
Housing assy for PMA2-...-3
551-32570-1
Housing assy for PMA2-...-4
551-32571-1
Housing assy for PMA2-...-5
551-32572-1
Housing assy for PMA2-...-6
551-32573-1
Arrangement of outlets
Number of outlets
Installation position
6
1 - 6
5
2 - 6
4
1, 3, 4, 6
3
1, 3, 5
2
2, 5
1
3
Installation of the proximity switch
N = proximity switch, part no. 234-13159-8
Tightening torque: 7 NM +10% SW 13
4 5 0 3 b 0 4
4 5 0 4 a 0 4
Fig. 17 Arrangement of outlets