A-4
INSTALLATION
A-4
INVERTEC STT II
INPUT VOLTAGE RECONNECT
PROCEDURE
As shipped from the factory, multiple voltage
(208/230/460 VAC) or (200/220/380 - 415/440 VAC)
machines are internally configured for the highest
input voltage (440 or 460 VAC).
1. For Connections to 440 or 460 VAC verify the inter-
nal configurations to the procedures shown below and
refer to Figure A.2.
2. For Connections to 200,208,220,230,380 or 415
VAC follow the procedure shown below and refer to
figure A.2.
NOTE: Turn main power to the machine OFF
before performing the reconnect procedure.
Failure to do so will result in damage to the
machine. DO NOT switch the reconnect bar with
machine power ON.
To Operate at
Procedure
460 or 440 VAC
1. Open reconnect panel
access door on wrap-around.
2. Move input voltage switch
to Voltage = 380 -460V pos-
ition.
3. Move lead “A” to 440-460
Terminal.
380 or 415 VAC
1. Open reconnect panel
access door on wrap-around.
2. Move input voltage switch
to Voltage = 380 -460V
position.
3. Move lead “A” to 380-415
Terminal.
220 or 230 VAC
1. Open reconnect panel
access door on wrap-around.
2. Move input voltage switch
to Voltage = 200 -230V
position.
3. Move lead “A” to 220-230
Terminal.
200 or 208 VAC
1. Open reconnect panel
access door on wrap-around.
2. Move input voltage switch
to Voltage = 200 -230V
position.
3. Move lead “A” to 200-208
Terminal.
OUTPUT CONNECTIONS
WIRE FEEDER OUTPUT CONNECTIONS
Refer to the Accessories section of this manual for
instructions on connecting a wire feeder to the
Invertec STT II.
The LN-742 or STT-10 wire feeder is the recommend-
ed feeder for use with the Invertec STT II.
4A
FIGURE A.2 RECONNECT PANEL