Impinger 3270 Service Manual – Dom & Int’l

 

13

TROUBLESHOOTING GUIDE - INTERNATIONAL 

 

Model Number 

Gas Type 

Voltage 

Hz. 

Phase 

3270 CE 

Natural Gas 

230 VAC 

50 Hz 

1 Phase 

3270 CE 

LP Gas 

230 VAC 

50 Hz 

1 Phase 

 

SYMPTOM 

POSSIBLE CAUSE 

EVALUATION 

 

Oven fan will not run 

 

Incoming Power Supply 

 

Check breakers, reset if required.  Check power plug to be 
sure it is firmly in receptacle.  Measure the incoming power.  
Call power company if needed. 

 

 

 

Fuse, 10 Amp 

 

Check, replace if necessary. 

 

 

 

Fuse Holder 

 

Check, replace if necessary. 

 

 

 

Emergency Stop Button 

 

 

This is a normally closed switch. Be sure button is re-set. 
Check continuity between switch terminals. If switch is 
open, replace Emergency stop button. 

 

 

 

Main Oven Switch 

 

Check continuity between terminals.  Replace if necessary. 

 

 

 

Time Delay Relay 

 

Check for line voltage to the relay coil.  If voltage is not 
present, trace wiring back to the oven power switch.  If 
voltage is present, check to insure contacts are closing. 
Replace as needed. 

 

 

 

Time Delay 

 

Line voltage is permanently supplied to terminal #1 of the 
time delay. If no voltage present trace wiring back to fuse 
and incoming power. Neutral side of time delay coil is 
switched by the time delay relay. When the time delay is 
enabled, line voltage is supplied to coil of main fan relay.  

 

 

 

Main Fan Relay 

 

Check for line voltage to main fan relay coil. If no voltage is 
present, trace wiring back to time delay. If line voltage is 
supplied to main fan relay coil, ensure the contacts of main 
fan relay are closing by checking for output voltage from 
relay contacts. If contacts are not closing, replace relay. 
Each terminal supplies a main fan motor with line voltage.  

 

 

 

Main Fan Motor 

 

Check for line voltage at motor.  If voltage is present and 
motor doesn’t turn, WITH POWER OFF, check for opens, 
shorts, or grounds.  Turn fan blade to check for locked 
rotor.  Replace as needed. 

 

 

 

Capacitor 

 

WARNING:  Capacitor has a stored charge, discharge 
before testing.  Check for shorts or grounds, replace as 
needed.  Inspect for any visible damage.  If the top of the 
capacitor appears to be swollen, replace capacitor. 

 

 

No control box cooling 

 

Incoming Power 

 

Check main circuit breakers and reset, if required.  Call 
power company if needed. 

 

 

 

Fuse, 10 Amp 

 

Check, replace if necessary. 

 

 

 

Fuse Holder 

 

Check, replace if necessary. 

 

 

 

Main Oven Switch 

 

Check continuity between terminals.  Replace if necessary. 

 

 

 

Cooling Fan(s) 

 

Line voltage should now be at the fan motor.  If voltage is 

Содержание Impinger 3270

Страница 1: ...coln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 Telephone 260 459 8200 Fax 888 790 8193 Technical Support 800 678 9511 lincolnfp com PARTS SERVICE MANUAL Impinger 3270 Im...

Страница 2: ...RAM INTERNATIONAL 7 TROUBLESHOOTING GUIDE DOMESTIC 8 TROUBLESHOOTING GUIDE INTERNATIONAL 13 REMOVAL INSTALLATION ADJUSTMENTS 18 OVEN CONTROL PROGRAMMING 25 GENERAL VIEW 27 CONTROL BOX LEFT SIDE DOMEST...

Страница 3: ...America T Mandarin China H Portuguese Portugal U Restricted I Not Used V English Pacific Rim Korea J Danish Denmark W English Middle East K Dutch French Belgium X Not Used L Dutch Netherlands Y Not Us...

Страница 4: ...ly 900 R P M to the primary of Ignition Control Transformers As the Burner Blower reaches approximately 1600 R P M its internal centrifugal switch will close supplying 24VAC to the ignition control Th...

Страница 5: ...air pressure switch through the normally closed oven cavity hi limit thermostat to the ignition control The combustion motor is now energized the normally open combustion air pressure switch closes u...

Страница 6: ...Impinger 3270 Service Manual Dom Int l 6 SCHEMATIC DIAGRAM DOMESTIC MODEL 3270 120V 60HZ 1PH NATURAL or LP GAS...

Страница 7: ...Impinger 3270 Service Manual Dom Int l 7 SCHEMATIC DIAGRAM INTERNATIONAL MODEL 3270 CE 230V 50HZ 1PH NATURAL or LP GAS...

Страница 8: ...Fan Relay Check for 120 VAC to main fan relay coil If no voltage is present trace back to time delay If 120 VAC is supplied to main fan relay coil ensure the contacts of main fan relay are closing by...

Страница 9: ...he oven power switch Check for 120 VAC out of the centrifugal switch If voltage is supplied to the centrifugal switch and motor is running but there is no voltage out of the centrifugal switch replace...

Страница 10: ...pen Check the output gas pressure at the pressure tap located on the burner manifold Gas pressure should measure approximately 6 in W C If there is no gas pressure and the voltage is supplied to valve...

Страница 11: ...per maintenance may cause this Also most of the problems listed under oven will not heat can cause intermittent failure Conveyor will not run Power Supply Check incoming voltage supply at line 1 to ne...

Страница 12: ...approx 10VDC If no voltage is present trace wiring back to the oven control If there is no voltage output present at the oven control replace the oven control Conveyor runs but no speed control Motor...

Страница 13: ...power Neutral side of time delay coil is switched by the time delay relay When the time delay is enabled line voltage is supplied to coil of main fan relay Main Fan Relay Check for line voltage to mai...

Страница 14: ...in Fan Motor Check air pressure switch terminals for supply voltage to terminals COM and NO If voltage is present on one side only check for air tube blockage or misalignment If these are okay adjust...

Страница 15: ...at terminal 5 and neutral If no voltage is present check reset button for the ignition control If there is still no voltage to the pilot valve replace ignition control Gas Control Valves Check for su...

Страница 16: ...re tap located on the burner manifold If voltage is present and gas pressure is not exceeding 6 in W C at the burner manifold replace modulating valve Intermittent heating Thermal Overload of Main Fan...

Страница 17: ...r components as needed Oven Control Check output voltage from oven control to hall effect sensor sensor is located in conveyor motor Measure voltage at the motor connector red wire and yellow wire Vol...

Страница 18: ...SHUTTER ADJUSTMENT It should be set at open HOT SURFACE IGNITOR REPLACEMENT DOMESTIC ONLY WITH POWER OFF A Remove appropriate control box cover B Disconnect gas line at union C Remove four 4 nuts fro...

Страница 19: ...l off black operating knob and remove hex mounting nut D Reassemble in reverse order BURNER ALARM REPLACEMENT INTERNATIONAL ONLY WITH POWER OFF A Remove appropriate control box cover B Remove 2 wires...

Страница 20: ...NIMUM OF 7 IN W C NATURAL AND 11 IN W C L P After installation check all gas line fittings for leaks FRONT VIEW MANIFOLD ADJUSTMENT SCREW LOCATED UNDER COVER SCREW TOP VIEW PILOT LINE CONNECTION MANIF...

Страница 21: ...old pressure to 6 in W C for NAT and 5 in W C for LP Replace cap and supply wire NOTE INLET GAS PRESSURE MUST BE A MINIMUM OF 7 IN W C NATURAL AND 11 IN W C L P After installation check all gas line f...

Страница 22: ...der and check system for operation RELAY REPLACEMENT WITH POWER OFF A Remove control box cover B Remove wires from relay being sure to note the wire numbers and location for reinstallation C Remove tw...

Страница 23: ...eated and making good contact When reinstalling gas manifold across back of oven check all fittings for leaks J Check system operation allow 30 minute preheat for all checks 1 875 INCH FROM CONE TO FA...

Страница 24: ...Before installing new oven control set voltage jumper located at the bottom center of the oven control to the proper voltage 120V 240V position Install the four pushbutton extensions included with th...

Страница 25: ...mming Shut off main fan switch Initialization of control is now complete 3 Set digital control for proper temperature scale F or C A Press and hold the 2RH buttons to enter sub level program The promp...

Страница 26: ...ature is below the set temperature increase button the offset value The amount of offset needed should be the difference between the cavity temperature and the set temperature Allow oven to reach set...

Страница 27: ...LATE IMPINGER I 371474 ACCESS DOOR FRAME ASM 3270 J 371171 WINDOW RETAINER 304S S K 371115 ACCESS DOOR GLASS 3200 L 370966 DOOR KNOB ASSY M 371140 BRACKET ASSEMBLY LH ACCESS DOOR SS N 371459 ACCESS DO...

Страница 28: ...Impinger 3270 Service Manual Dom Int l 28 GENERAL VIEW A B C D B U V A G J H I L K N O P Q R S N M T W W V X Y Z F J E...

Страница 29: ...24VDC 1 2 INCH LH LP G 369552 IGNITOR HOT SURFACE H 371008 THERMOCOUPLE TYPE K W PLUG I 369366 KIT BURNER BLOWER MTR J 369401 SHUTTER AIR ASSY 4071149 K 390131 SNAP BUSHING HEYCO WP750 L 369568 VENTU...

Страница 30: ...Impinger 3270 Service Manual Dom Int l 30 CONTROL BOX LEFT SIDE DOMESTIC A R O Q P E D C B S T U G K I J N L M H F Auto Quest Parts Only...

Страница 31: ...H LP I 369263 NATURAL GAS CONT ASSY J 369124 COOLING FAN K 369331 FINGER GUARD L 369532 IGNITION CONTROL 2FT M 370359 SWITCH CNVYR REVRS ASSY N 369508 TIMER 20 MIN O 370352 CAPACITOR 115V DIGITAL P 36...

Страница 32: ...ervice Manual Dom Int l 32 CONTROL BOX RIGHT SIDE DOMESTIC Auto Quest Parts Only Duplicated Parts for Split Belt Oven Shown on Illustration U Q M N L K Y H G F E C D B A J I Z X T R S P V W O AB AC AD...

Страница 33: ...773 VENTURI SPARK LP G 390131 SNAP BUSHING HEYCO WP750 H 370397 SPARK IGNITOR ASSY I 369401 SHUTTER AIR ASSY 4071149 J 369589 MOTOR BLOWER K 369579 ALARM 250V SOLID STAT L 370673 AIRSWITCH PS100 GOLDT...

Страница 34: ...Impinger 3270 Service Manual Dom Int l 34 CONTROL BOX LEFT SIDE INTERNATIONAL U S R Q X W M L J H F D C P T L V O K I Y G E B A N...

Страница 35: ...AIR ASSY 4071149 R 370674 SURGE PROTECTOR S 370360 CAPACITOR 230V DIGITAL T 370184 FILTER RFI U 369125 TERMINAL BLOCK V 370397 SPARK IGNITOR ASSY W 390131 SNAP BUSHING HEYCO WP750 X 369937 VENTURI SP...

Страница 36: ...Impinger 3270 Service Manual Dom Int l 36 CONTROL BOX RIGHT SIDE INTERNATIONAL AB AI AJ AK AL H AM A O V U T S AD AE AF AG AH J L M N G F E D C B Y X Q P H I K AC Z AA R W...

Страница 37: ...69213 FAN ASSY 3FT C 369777 ROD STAND OFF L P D 371473 REAR WALL ASM E 369215 MOTOR SUPPORT ASSY F 369800 MOTOR BLOWER ADV 3 60HZ 120V 369214 MOTOR 50HZ 230V G 369033 CLAMP MOTOR H 357003 CLAMP HOSE I...

Страница 38: ...Impinger 3270 Service Manual Dom Int l 38 REAR WALL MOTOR ASSEMBLY A L K J I H L G F E D B C M...

Страница 39: ...SIONER FULL BELT ASSEMBLY D 370990 BEARING BLOCK ASSY 3255 E 371004 SHAFT DRIVE END 32 F 371464 CONVEYOR FRAME WELD FULL BELT G 371006 CONVEYOR BUSHING ASSY H 369039 GEAR DRIVE BLANK I 369038 GEAR DRI...

Страница 40: ...Impinger 3270 Service Manual Dom Int l 40 CONVEYOR FULL BELT N A B C D L K J G I H E M O F P B C D I H...

Страница 41: ...NER ASSY D 369002 CONVEYOR TENSION KNOB E 369038 GEAR DRIVE NOTCHED F 369039 GEAR DRIVE BLANK G 370994 SHAFT IDLE END 32 H I 390119 ZERO STOP SB 32 J 370996 CONVEYOR BUSHING ASSY K 371204 SPROCKET 1 2...

Страница 42: ...Impinger 3270 Service Manual Dom Int l 42 CONVEYOR SPLIT BELT A E H P J L E K J O Q N M E I G B F A C F F D F C B...

Страница 43: ...Impinger 3270 Service Manual Dom Int l 43...

Отзывы: