B-6
OPERATION
B-6
FLEXTEC™ 450
INTERNAL CONTROLS - ENABLING VRD
™
(For Code 11941 only)
Internal Controls Description
The Control PC Board has one bank of Dip Switches.
As shipped from the factory VRD™ mode is disabled
and the Dip Switches are all in the “off” position.
To Enter
VRD™ Mode (VRD™ Enabled)
a. For
380V input
: Switch
#5
in the “ON”
Position.
b. For
460V input
: Switch
#6
in the “ON”
Position.
c. For
575V input:
Switch
#5 and #6
in the
“ON” Position
1 2 3 4 5 6 7 8
ON
OFF
DIP SWITCH LOCATION
CONTROL PCB
CONTROL PCB LOCATION
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
FIGURE B.3