C-2
ACCESSORIES
C-2
The CV-655 can be used to power any of
the following Lincoln Wire feeders:
SEMI-AUTOMATIC WIRE FEEDERS
•
DH-10
•
LN-9*
•
LN-10
•
LN-9 GMA*
•
LN-7 GMA*
•
LN-23P
•
LN-742
•
LN-25
•
LN-7
•
LN-8*
AUTOMATIC WIRE FEEDERS*
#
•
NA-3
•
NA-5R
•
NA-5
* European CV-655 models only provide 115VAC for these feeders at the ter-
minal strip (TS2)
#
“Cold starting for sub-arc cannot be used. (It must be jumpered out. See
Auto Feeder manual)
FIELD INSTALLED OPTIONS
K1482-1 Digital Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides digital dis-
play of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).
K1483-1 Analog Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides analog
display of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).
K1484-1 Dual Feeder Kit - This kit replaces the 14 Pin
MS-receptacle panel on the lower case front of the CV-
655. It provides two 14 Pin MS-receptacles and a built
in transfer circuit for connecting and operating two like-
polarity wire feeders. European CV-655 models can
only use 42V feeders with this kit. (Installation instruc-
tions are included with the kit).
K1485-1 Cable Hanger Bracket - Mounts over stan-
dard lift bale of the CV-655 and provides a cable hang-
er on both sides of the power source, each side capa-
ble of holding up to 100 ft. of weld cable. (Installation
instructions are included with the kit).
K1486-1 Air Filter Kit - Removable metal filter easily
slides in and out of a bracket which mounts to the front
of the CV-655. Filter is designed to trap 80% of enter-
ing particles which are 5 microns, or larger, in size.
(Installation instructions are included with the kit).
NOTE: A dirty air filter may cause the thermal protec-
tion of the CV-655 to prematurely activate. Remove
and blow out, or wash and dry, the filter every two
months, or less if in extremely dirty conditions. Replace
if necessary.
Undercarriage (K817P, K842) - The CV-655 is
designed for use with the Lincoln K817P or K842
Undercarriage. Complete installation instructions are
included with each undercarriage. When any of the
undercarriages are installed, the CV-655 lift bail is no
longer functional. Do not attempt to lift the machine
with the undercarriage attached. The undercarriage is
designed for moving the machine by hand only.
Mechanized towing can lead to injury and /or damage
to the CV-655.
REMOTE OUTPUT CONTROL
(K775 or K857 WITH K864 ADAPTER)
An optional “remote output control” is available. This is the
same remote control that is used on other Lincoln power
sources (K775). The K775 consists of a control box with
28 ft (8.5m) of four conductor cable. This connects to
terminals 75, 76, and 77 on the terminal strip and the case
grounding screw so marked with the symbol on the
machine. These terminals are located behind the cover
panel on the lower connection panel of the CV-655. This
control will give the same control as the output control on
the machine.
The K857 has a 6-pin MS-style connector. The K857
requires a K864 adapter cable which connects to the
14-pin connector on the CV-655.
REMOTE CONTROL ADAPTER CABLE (K864)
A “V” cable 12” (.30m) long to connect a K857 Remote
Control (6 pin connector) with a wire-feeder (14-pin
connector) and the machine (14-pin connector). If a
remote control is used alone the wire-feeder connec-
tion is then not used.
S T R A I G H T P L U G ( 1 4 P I N )
T O P O W E R S O U R C E
C A B L E R E C E P T A C L E ( 6 S O C K E T )
C A B L E R E C E P T A C L E ( 1 4 S O C K E T )
T O : K 8 5 7 R E M O T E C O N T R O L
T O : L N - 7 W I R E F E E D E R S