Page Number - 4
Form 404308
NOTE:
A24” length of 1/2” I.D. hose must be
used at the material inlet to prevent
hydraulic lock which may occur if rigid
piping is used.
SPECIFICATIONS
Priming Pressure
Air Pressure
Output Per Cycle
Ratio
Adjustment Rate
Max. Air Req’d./Cycle
Wetted Parts
1,500 PSI Max.
100 PSI Max.
.015 in³ to .200 in
3
35:1
.010 in
3
per turn
13 in³
Carbon Steel Body
Viton. Polyurethane &
EPDM or Nitrile©
3-7/8”
1”
9/32” Slots
For Mounting
2-15/16”
2-1/2”
1-1/4”
7/16”
6-7/8”
13-3/4”
RETAIN THIS INFORMATION FOR FUTURE REFERENCE
When ordering replacement parts, list: Part Number, Description, Model Number and Series Letter.
LINCOLN provides a Distributor Network that stocks equipment and replacement parts.
© Indicates change