Technical data 

 

Pressure ratio (practical): approx....................... 6.6 :1 

Lubricant output per double stroke: ................... 30 cm³ 
Output pressure: ................................................ max.295 bar 
 
Lubricant output at 4,5l/min, 45 bar oil pressure:  360 
cm³/min 
(corresponds to 12 double strokes/min) 
Ambient temperature: ........................................ -20 to +60° C 
Sound pressure level: ........................................ <70 dB(A) 
 
Quantity of hydraulic oil:..................................... max. 10 l/min 
Pressure of hydraulic oil:.................................... 45 - 50 bar 
Oil viscosity: ....................................................... 22 mm²/s (at 
40°C) 
Filtration required: .............................................. 10 

K

m

Electrical equipment

 

Low level indicators (capacitive) 

 

 

2/2-way solenoid valve for grease, 24 VDC, G 1/2" type 2/2-
500-GS2-2-1/2-G24 

     part. 

no. 

235-13185-1 

2/2-way solenoid valve for hydraulic oil, 24 VDC G 3/8   
 

part no. 235-13181-5 

 

Erection and installation 

 

Erection of the pump 
 

Requirements for the installation site:

even and stable installation site 

free space for maintenance work 

 

Electric connection 
 

All electrical works should be carried out only by 
qualified personnel. 

 
Carry out the electric connection in accordance with the 
terminal diagram. 

Operating instruction 
Start up 

 

Connect only clean supply lines and supply hoses to the 
pump.

 

Before starting the pump, be sure that all connections 
(particularly the hydraulic connections) are tight. 
Read and observe the recommendations of the manufacturer 
of the hydraulic fluid as regards compatibility. Use protective 
clothes and devices. 
 

The pump may only be started if the lubricant container is 
full. 
When refilling take care that no dirt or foreign bodies 
enter into the container. 
 

The hydraulic oil for the drive must be free from condensate 
and impurities. Filtration required: 10

K

m. 

 

The pressure regulator for the hydraulic oil is set at 45 
bar. Do not change this setting. 
All component parts of the lubrication system (tubes, 
hoses, tube fittings, etc.) must be designed for the 
highest system pressure. 
 

Filling of the 165 l-container: 

 
Once the minimal grease level is reached in the reservoir, the 
ultrasonic sensor gives a signal to the electric control unit. 
The container has to be refilled immediately. 
 

Stop refilling when grease is escaping from the 
overfilling safety valve ('X' in figure 1) 

The sealing of the follower plate could be damaged if 
the filling pressure is to high 

Do not close the opening of the overfilling safety 
valve

 

Содержание 609-29232-1

Страница 1: ...life of the pump lubrication system must be supplemented by the respective national regulations concerning the prevention of accidents and protection of the environment Safety Instructions The Operati...

Страница 2: ...llation Services The user must make sure that all maintenance inspection and installation work is executed by authorized and qualified experts who have thoroughly read the Operating Instructions On no...

Страница 3: ...ressure reducing valve X Overfilling safety valve The pump 609 328839 1 consists of the following main components Item Description Part No Item Description Part No 1 Grease reservoir assy 509 32544 1...

Страница 4: ...id valve has opened pressure of the hydraulic system is applied on the connection P The cylinder first retracts at the start irrespective of the direction it had when it was switched off Once the cyli...

Страница 5: ...he electric connection in accordance with the terminal diagram Operating instruction Start up Connect only clean supply lines and supply hoses to the pump Before starting the pump be sure that all con...

Страница 6: ...e oil quantity After completing the adjustment tighten the set screw with the counter nut item 3 SW 17 2 Pressure reducing valve item 2 The max inlet pressure is 200 bar The pressure reducing valve al...

Страница 7: ...ube and unscrew the line hose Maintenance inspection and repair work may be carried out only by qualified personnel Troubleshooting Fault Pump does not deliver Cause Remedy Hydraulic pressure supply i...

Страница 8: ...ed rod item 2 into cylinder head of oscillating cylinder and tighten firmly sticked in with Loctite 274 2 Mount oscillating cylinder to upper part of pump tube Handscrew the 4 self locking hexagon nut...

Страница 9: ...hrough 36 from adapter tube 28 5 Remove cotter pin 32 from bushing plunger part of 31 6 Remove priming shovel nut 36 from bushing plunger 31 7 Remove retaining ring 29 and guide washer 30 from bushing...

Страница 10: ...Parts for Hydraulic Pump Part No 509 32178 1 Fig 4 Spare parts of the hydraulic pump Item Description Qty Part number 1 OSCILLATING CYLINDER ASSY WITH CONTROL BLOCK 1 235 13183 1 2 PRESSURE REDUCING...

Страница 11: ...to protect all components against damage and dirt Collect and dispose of leaking fluids in such way that there do not arise any personal or environmental hazards Adhere to legal requirements Cross Sec...

Страница 12: ...it consisting of connecting block and piston rod sideward Pull the tube pos 420 out of the cylinder head Remove the groove nut pos 470 with a hook wrench and then remove the connecting block pos 440 U...

Страница 13: ...mounting and calibrating sleeve is available as special accessory Cylinder Lightly oil piston unit pos 60 and the thread of the cylinder tube pos 10 Carefully stick together components without using...

Страница 14: ...le line with 165 l container 4 1EN 68607 G09 Subject to changes Page 14 of 15 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Spare parts drawing Pump tube 84997 Cautio...

Страница 15: ...IMING PLUG 1 16 382 11 ADAPTER 1 16 381 12 GASKET copper 2 13 OUTLET CHECK 1 11 948 14 BALL 1 66 285 15 BALL STOP 1 57 036 16 OUTLET BODY 1 12 017 17 O RING nitrile 1 18 PUMP TUBE 1 242 373 19 ADAPTER...

Отзывы: