Owner’s Manual
Hydraulic pump 609-29232-1 Single-line with 165-l container
4.1EN-68607-G09
Subject to changes
Page 5 of 15
LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Technical data
Pressure ratio (practical): approx....................... 6.6 :1
Lubricant output per double stroke: ................... 30 cm³
Output pressure: ................................................ max.295 bar
Lubricant output at 4,5l/min, 45 bar oil pressure: 360
cm³/min
(corresponds to 12 double strokes/min)
Ambient temperature: ........................................ -20 to +60° C
Sound pressure level: ........................................ <70 dB(A)
Quantity of hydraulic oil:..................................... max. 10 l/min
Pressure of hydraulic oil:.................................... 45 - 50 bar
Oil viscosity: ....................................................... 22 mm²/s (at
40°C)
Filtration required: .............................................. 10
K
m
Electrical equipment
Low level indicators (capacitive)
2/2-way solenoid valve for grease, 24 VDC, G 1/2" type 2/2-
500-GS2-2-1/2-G24
part.
no.
235-13185-1
2/2-way solenoid valve for hydraulic oil, 24 VDC G 3/8
part no. 235-13181-5
Erection and installation
Erection of the pump
Requirements for the installation site:
•
even and stable installation site
•
free space for maintenance work
Electric connection
All electrical works should be carried out only by
qualified personnel.
Carry out the electric connection in accordance with the
terminal diagram.
Operating instruction
Start up
Connect only clean supply lines and supply hoses to the
pump.
Before starting the pump, be sure that all connections
(particularly the hydraulic connections) are tight.
Read and observe the recommendations of the manufacturer
of the hydraulic fluid as regards compatibility. Use protective
clothes and devices.
The pump may only be started if the lubricant container is
full.
When refilling take care that no dirt or foreign bodies
enter into the container.
The hydraulic oil for the drive must be free from condensate
and impurities. Filtration required: 10
K
m.
The pressure regulator for the hydraulic oil is set at 45
bar. Do not change this setting.
All component parts of the lubrication system (tubes,
hoses, tube fittings, etc.) must be designed for the
highest system pressure.
Filling of the 165 l-container:
Once the minimal grease level is reached in the reservoir, the
ultrasonic sensor gives a signal to the electric control unit.
The container has to be refilled immediately.
•
Stop refilling when grease is escaping from the
overfilling safety valve ('X' in figure 1)
•
The sealing of the follower plate could be damaged if
the filling pressure is to high
•
Do not close the opening of the overfilling safety
valve