Do not exceed 3,000 PSIG (200 bar) maximum supply inlet
hydraulic pressure. Exceeding the rated pressure may result
in damage to system components and personal injury.
Pump Performance and Specification
Supply inlet hydraulic pressure,
maximum, PSIG (bar) -
3,000 (200)
Operating working hydraulic
pressure , PSIG (bar) -
300 to 450 (20 to 32).
Hydraulic Inlet Flow,
GPM (l/min) -
Up to 7 (28)
Pump Ratio with manifold -
9:1 at low inlet pressure
(300 to 350 psi [20 to 25
bar]) and low inlet flow
(below 2 gpm [7 lpm])
Pump ratio approaches
11.0:1 ratio at higher
inlet pressure and flow.
Hydraulic Manifold
Operating Temperature, ºF (ºC)-
-20 to +150 (-10 to 65)
Operating Voltage, VDC -
24
Hydraulic Inlet Port, In -
3/8 NPTF
Tank Return Port, In -
3/8 NPTF
Pump Outlets, In -
1/4 NPTF
Maximum Hydraulic
Fluid Temperature, ºF, (ºC) -
200 (93)
©
Weight, Lbs (Kg) -
36 (16)
HYDRAULIC PUMP PERFORMANCE SPECIFICATIONS
Test conducted with Alvania NLGI # 2 Grade Grease
Grease Output
1,000 psi Backpressure
Cubic inches/min. (cm³/min.)
(70 bar)
Hydraulic Flow Input
Temperature F
1 gpm
2 gpm
3 gpm
4 gpm
5 gpm
6 gpm
7gpm
(Temperature C)
(4 l/min)
(8 l/min) (11 l/min) (15 l/min) (19 l/min) (23 l/min) (26 l/min)
80
7
14
21
28
34
40
45
(27)
(115)
(229)
(344)
(459)
(557)
(656)
(737)
40
7
14
21
28
33
38
41
(4)
(115)
(229)
(344)
(459)
(541)
(623)
(642)
20
6
13
17
22
28
32
36
(-7)
(98)
(213)
(279)
(361)
(459)
(594)
(590)
0
6
11
15
19
23
27
30
(-18)
(98)
(180)
(245)
(310)
(376)
(442)
(491)
-10
5
7
8
9
10
12
13
(-23)
(82)
(115)
(131)
(148)
(164)
(197)
(213)
-20
4
6
8
10
12
14
15
(-29)
(66)
(98)
(131)
(164)
(197)
(229)
(245)
Hydraulic
Fluid Inlet
Hydraulic
Fluid Return
to Tank
Solenoid Valve
(Items 34 & 35)
Pressure Reducing
Valve (Item 38)
Vent
Valve
Pressure Gauge
(Item 32)
Flow Control
Valve (Item 39)
Hydraulic Motor
(Item 42)
Material
Outlet
Illustration 1