SAFETY INSTRUCTIONS

This equipment generates very high

grease  pressure.  Extreme  caution

should be used when operating this

equipment  as  material  leaks  from

loose or ruptured components can

inject fluid through the skin and into the

body causing serious bodily injury

including  possible  need  for

amputation. Adequate protection is

recommended  to  prevent  splashing  of

material onto the skin or into the eyes.

IMPORTANT

If any fluid appears to penetrate the

skin, get emergency medical care

immediately. Do not treat as a simple

cut. Tell attending physician exactly

what fluid was injected.

DO NOT alter or modify any part of the

equipment as this may cause a

malfunction  and  result  in  serious

bodily injury.

INSPECTION

If  overpressurizing  of  the  equipment  is

believed  to  have  occurred,  contact  the

factory authorized warranty and service

center nearest you for inspection of the

pump.

Specialized  equipment  and  knowledge

is required for repair of this pump.

Contact the factory authorized warranty

and service center nearest you for

repair or adjustments other than

Annual inspection by the factory

authorized warranty and service center

nearest  you  is  recommended.

A list of factory authorized warranty and

service centers is available upon

request.

DAMAGED PUMPS

Any pump that appears to be damaged

in any way, is badly worn or operates

abnormally shall be removed from use

until repairs are made. Contact the

factory authorized warranty and service

center nearest you for repairs.

11 3/16"

(284 mm)

1"  (25 mm)

DIA. PUMP TUBE

3/4"

(19 mm)

1-13/16"

(46 mm)

1/4"

NPTF PORTS

NOTE:

 242207 Pressure Reducing

Valve is factory set @ 300 PSI.

Turn clockwise to increase

pressure.

NOTE:

 For Centro-matic applications,

connect port to top of Vent Valve

with high pressure 1/4" hose. For

Mod-Lube applications, plug port.

FIGURE (1) GENERAL INFORMATION

INSTALLATION

See Figures (1) and (2). A typical

installation is shown only as a guide for

 

15-1/4"

(387 mm)

7"

(178 mm)

3"

(76 mm)

maintenance  specified  in  this  manual.

Содержание 84960

Страница 1: ...ing and maintenance instructions SPECIFICATIONS POWER REQUIREMENTS SV1 SV2 6 Amps 24 VDC each RATIO SeeNoteinFig 2 16 1 INPUTPRESSURE 300 3500 P S I INPUT FLOW 30 CYCLES PER MINUTE 1 0 G P M MAXIMUMHYDRAULICTEMP 210 F OUTPUTPRESSURE 7500P S I MAX OUTPUTFLOW 30 CYCLES PER MINUTE 11 CU IN MIN AMBIENTTEMP 40 TO 135 F SEALS POLYURETHANEANDNITRILE FILTRATIONREQUIRED 10 MICRON Failure to heed the follow...

Страница 2: ...ve occurred contact the factory authorized warranty and service center nearest you for inspection of the pump Specialized equipment and knowledge is required for repair of this pump Contact the factory authorized warranty and service center nearest you for repair or adjustments other than Annual inspection by the factory authorized warranty and service center nearest you is recommended A list of f...

Страница 3: ... the pressure reducing valve D The pressure reducing valve lowers hydraulic fluid pressure to the operating range of the hydraulic pump selecting and installing system components Contact your Lincoln representative for assistance in designing a system to suit your specific need system This is to purge any contamination such as dirt moisture or metal shavings that could damage the pump or system co...

Страница 4: ...eved and the The adjustment screw allows 15 turns of adjustment over the timing range The adjustment screw should be turned 20 turns counter clockwise to insure you are starting at minimum Note You can not adjust below minimum additional turns counter clockwise have no effect E After the system pressure has been reduced it passes on to SV2 which controls the direction of the hydraulic cylinder whi...

Страница 5: ...check parts and plunger rod 11723 O Remove bushing extension 61273 and unscrew plunger and bushing assembly 90554 from pump tube Unscrew coupling nut 11345 from plunger adapter 11344 to allow removal of plunger and bushing assembly intact reducing the chance of loosing ball stop 57027 and check ball 66010 Each clockwise turn will equal approx imately 3 seconds Add the number of turns clockwise to ...

Страница 6: ...Page 6 Form 403122 1 6 241803 See Torque Specifications on Page 7 for all keyed notes 27 3 8 695 mm 18 7 8 479 mm 33 15 16 862 mm 271598 271599 120 lbs 54 Kg 50 lbs 23 Kg 400 lbs 181 Kg ...

Страница 7: ...for incidental or consequential damages The liability of Lincoln on any claim for loss or damage arising out of the sale resale or use of lubrication equipment materials dispensing equipment and other related equipment shall in no event exceed the purchaseprice SOMESTATESDONOTALLOWTHEEXCLUSIONORLIMITATIONOFINCIDENTALORCONSEQUENTIALDAMAGES SOTHE ABOVELIMIATAIONOREXCLUSIONMAYNOTAPPLYTOYOU THISWARRAN...

Страница 8: ... RETAIN THIS INFORMATION FOR FUTURE REFERENCE When ordering replacement parts list Part Number Description Model Number and Series Letter LINCOLN provides a Distributor Network that stocks equipment and replacement parts ...

Отзывы: