D-1
TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln
Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Contact your local Lincoln Authorized
Field Service Facility.
X-TRACTOR 1GC
CAUTION
Poor Suction
Motor not Running in Auto or Manual
Will not sense current
Cover will not fasten to case
1. Leakage
2. Filter too dirty
3. Improper application
4. Filter blocked
5. Brushes worn in one of the motors
1. Brushes worn
2. Circuit breaker tripped
1. Operating current too low
2. Current sensor or P.C. board damaged
1. Fasteners not lined up
1. Check: Hose connections, Hose integrity
2. Clean the filter, check for oily conditions
3. Check: Hose dia. & length; Check filter for
oily conditions
4. Replace filter
5. Replace brushes in both motors
1. Check brushes, replace if worn
2. Reset circuit breaker (See Electrical
Maintenance)
1. Loop cable in hook two or three times
2. Replace sensor or P.C. board
1. Check procedure in “Emptying the
2. Canister and Heavy Particle Trap” (Step 7)
Содержание X-Tractor 1GC
Страница 17: ...NOTES...