OUTPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT
(continued)
11. With the 7/16" wrench, install the choke
lead and the #203 lead to the positive
heat sink.
12. With the 7/16" wrench, install the "N"
negative lead and the #204 lead to the
negative heat sink.
13. With the 7/16" wrench, install the heavy
leads W1 and W2 to the stud terminals.
14. Replace the top cover of the control box
and tighten the 8 sheet metal screws with
the 5/16" nut driver.
TROUBLESHOOTING & REPAIR
F-49
F-49
WELDANPOWER 125