English
English
2
MACHINE SPECIFICATIONS
RECEPTACLES
AUXILIARY POWER CIRCUIT
BREAKER
OTHER CIRCUIT BREAKERS
(1) 115V Euro Style
(1) 230V Euro Style
(1) 400V Euro Style
(2) 30Amp for Single Phase
(1) 15Amp for Single Phase
(1) 16Amp for Three Phase (3-pole)
10AMP for Engine Battery Charging
Circuit
10AMP for 42V Wire Feeder Power
Residual Current Device (RCD)
4-pole, 25AMP x 1
1 Phase, 15AMP x 1 for 230V
30AMP x 2 for 115V
MISCELLANEOUS
HARMONIC CONTENT
EMC CLASSIFICATION
6.2% THF.
THF < 8% :
VANTAGE 410 CE IS CLASSIFIED AS A CLASS I MACHINE
MACHINE AMBIENT OPERATING CONDITIONS
TEMPERATURE
ALTITUDE
MAX ANGLE OF OPERATION
5°F (-15°C) TO 104°F (+ 40°C)
5997ft (1828m)*
15° ALL DIRECTIONS
* For use above 5997ft (1828m), contact Authorized Field Service Shop.
TRANSPORTATION & STORAGE TEMPERATURES
-13°F (-25°C) TO 131°F (+55°C) NOT EXCEEDING 158° (70°C) FOR 24 HOURS