![Lincoln Electric SVM188-A Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/lincoln-electric/svm188-a/svm188-a_service-manual_1918711060.webp)
DC600 CONTROL G3409-1
LED1
LED5
LED2
LED3
LED4
LED6
J2
J3
J1
2 (256)
(290) 7
(291) 8
1
(222)12
1 (210)
5 (231)
(255) 6
1
FIGURE F.7 CONTROL BOARD
CONTROL BOARD TEST (continued)
PROCEDURE
ELECTRIC SHOCK
can kill.
• Do not touch electrically hot parts.
1.
Turn the POWER Switch ON. LEDs 1 and 3 should
turn ON.
2.
If
LED 1
does not come ON, but the Power Light
is ON, check for 120vac at J2 (pin 6 and pin 2).
See the
Wiring Diagram.
• If the Power Light is not ON, perform the
Control
Transformer Voltage Tes
t and check the Power
Switch and associated wiring.
3.
If
LED 3
does not come ON but LED4 is ON, the
DC-600 has shut down due to over-current or a
fault in the control leads (75,76 & 77).
• Disconnect any control cables, welding leads or
jumpers from the terminal strips (TS1& TS2).
4. If the machine stays ON and all LEDs are correct,
the problem is external to the machine. If LED4 still
comes ON:
• Check the Output Studs and associated wiring for
a ‘shorted’ or ‘grounded’ condition.
• Check for grounds in the control circuit (Output
Control, Local/Remote Switch & TS1).
• Control Board may be defective.
NOTE
: LED 4 should be OFF except in a “shutdown“
condition. If ON and machine is still function-
ing, replace the Control Board.
5.
LED 5
indicates a signal to the Firing Board and
should vary in brilliance as the Output Control is
adjusted. If LED 5 is not ON or does not change:
• Make certain that LED 6 is ON. The Output
Terminal Switch the Local/Remote Switch must
be in “LOCAL” position and the Mode Switch in
CV. If switches are set properly and functional, the
Control Board may be defective.
6.
LED 6
indicates a signal from the Firing Board that
the DC-600 is “triggered”. If not ON, perform the
Internal Trigger Test
.
TROUBLESHOOTING AND REPAIR
F-20
F-20
DC-600
Retur
n
to
Section
T
OC
Retur
n
to
Section
T
OC
Retur
n
to
Section
T
OC
Retur
n
to
Section
T
OC
Retur
n
to
Master
T
OC
Retur
n
to
Master
T
OC
Retur
n
to
Master
T
OC
Retur
n
to
Master
T
OC
WARNING