background image

English 8 English 

Intoduction 

 

SPEEDTEC 405S, 405SP, 505S

 and 

505SP

 inverter 

sources have been designed to work with wire feeders 

PF24

PF40, PF42,

 

PF44

PF46

LF45

LF45S

. For 

communication, inverter source-wire feeder is using 
ArcLink

®

 protocol. 

Inverter source-wire feed configuration allows the welding: 

 GMAW 

(MIG/MAG) 

  FCAW-GS / FCAW-SS 

 SMAW 

(MMA) 

  GTAW (arc ignition using lift TIG). 

 

SPEEDTEC 405S, 405SP, 505S and 505SP

 work with 

the water cooler 

COOLARC 46

 
The complete packaging includes the following items: 

 Inverter 

source 

  DVD with Operator’s Manual 

  Work lead - 3m 

  Slow-blow fuse – 2A (2 units) 

  Slow-blow fuse – 6,3A (1 unit) 

  Slow –blow fuse – 12.5A (1 unit). 

 
Recommended equipment, which can be bought by user, 
was mentioned in the chapter "Accessories". 
 

 

Installation and Operator Instructions 

 
Read this entire section before installation or operation of 
the machine. 
 

Location and Environment 

This machine will operate in harsh environments. 

 

However, it is important that simple preventative 
measures are followed to assure long life and reliable 
operation. 

  Do not place or operate this machine on a surface with 

an incline greater than 15° from horizontal. 

  Do not use this machine for pipe thawing. 

  This machine must be located where there is free 

circulation of clean air without restrictions for air 
movement to and from the air vents.  Do not cover the 
machine with paper, cloth or rags when switched on. 

  Dirt and dust that can be drawn into the machine 

should be kept to a minimum. 

  This machine has a protection rating of IP23.  Keep it 

dry when possible and do not place it on wet ground 
or in puddles. 

  Locate the machine away from radio controlled 

machinery.  Normal operation may adversely affect 
the operation of nearby radio controlled machinery, 
which may result in injury or equipment damage.  
Read the section on electromagnetic compatibility in 
this manual. 

  Do not operate in areas with an ambient temperature 

greater than 40°C. 

 

Duty cycle and Overheating 

The duty cycle of a welding machine is the percentage of 
time in a 10 minute cycle at which the welder can operate 
the machine at rated welding current. 
 
Example: 60% duty cycle 
 

 

Welding for 6 minutes. 

Break for 4 minutes. 

 
Excessive extension of the duty cycle will cause the 
thermal protection circuit to activate. 
 

 

 Minutes 

 

or 

decrease 

duty cycle 

 

 

Input Supply Connection 

 

 WARNING 

Only a qualified electrician can connect the welding 
machine to the supply network. Installation the outlet plug 
to power lead and connecting the welding machine had to 
be made in accordance with the appropriate National 
Electrical Code and local regulations. 
 
Check the input voltage, phase, and frequency supplied to 
this machine before turning it on. Verify the connection of 
grounding wires from the machine to the input source. 

SPEEDTEC 405S, 405SP, 505S 

and

 505SP

 can only be 

connected to a mating grounded receptacle. 
Input voltages is 3x400V 50/60Hz. For more information 
about input supply refer to the technical specification 
section of this manual and to the rating plate of the 
machine. 
 
Make sure that the amount of mains power available from 
the input supply is adequate for normal operation of the 
machine. The type of protection and cable sizes are 
indicated in the technical specification section of this 
manual. 
 

 WARNING

 

The welding machine can be supplied from a power 
generator of output power at least 30% larger than input 
power of the welding machine. 
See "Technical Specifications" chapter. 
 

 WARNING

 

When powering welder from a generator be sure to turn 
off welding machine first, before generator is shut down, in 
order to prevent damage to welding machine! 
 
Refer to points [1], and [8] of the images below. 
 

Output Connections 

Refer to points [5], [6] and [7] of the Figures below. 

Содержание SPEEDTEC 405S

Страница 1: ...IM3048 08 2020 REV09 SPEEDTEC 405S 405SP 505S 505SP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Страница 2: ...ie na tej stronie danych identyfikacyjnych wyrobów Nazwa modelu Kod i Numer Seryjny które możecie Państwo znaleźć na tabliczce znamionowej wyrobu Nazwa Modelu Kod i Numer Seryjny Data i miejsce zakupu ENGLISH INDEX Technical Specifications 1 ECO design information 3 Electromagnetic Compatibility EMC 5 Safety 6 Intoduction 8 Installation and Operator Instructions 8 WEEE 13 Spare Parts 13 REACh 13 A...

Страница 3: ...ent Output Voltage 405S 405SP GMAW 60Vdc 80 400A 34Vdc 100 390A 33 5Vdc FCAW 60Vdc 80 400A 34Vdc 100 390A 33 5Vdc SMAW 60Vdc 80 400A 36Vdc 100 390A 35 6Vdc GTAW 60Vdc 80 400A 26Vdc 100 390A 25 6Vdc 505S 505SP GMAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc FCAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc SMAW 60Vdc 60 500A 40Vdc 100 390A 35 6Vdc GTAW 60Vdc 60 500A 30Vdc 100 390A 25 6Vdc WELDING CURRENT RANGE G...

Страница 4: ...h 405S 405SP 50 kg 535 mm 300 mm 635 mm 505S 505SP 50 kg 535 mm 300 mm 635 mm Protection Rating Operating Humidity t 20 C 405S 405SP IP23 90 505S 505SP Operating Temperature Storage Temperature 405S 405SP from 10 ºC to 40 ºC from 25 ºC to 55 ºC 505S 505SP ...

Страница 5: ...e condition specified in below table IDLE STATE Condition Presence MIG mode X TIG mode STICK mode After 30 minutes of non working Fan off X The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 20XX Manufacturer s name product name code number product number serial number and date of production can be read from ...

Страница 6: ... process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may aspirate atmospheric contamination into the welding pool Notice A cross wind or draft moving can disrupt the shielding gas coverage in the interest of saving of protective gas use screen to block air...

Страница 7: ...ds Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area and other activities that are taking place Consider the following guidelines to reduce electromagnetic emi...

Страница 8: ...al electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the electrode holder directly on the welding table or any other surface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric curre...

Страница 9: ...ing gas for the process used and properly operating regulators designed for the gas and pressure used Always keep cylinders in an upright position securely chained to a fixed support Do not move or transport gas cylinders with the protection cap removed Do not allow the electrode electrode holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be located a...

Страница 10: ...jury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle and Overheating The duty cycle of a welding machine is the percentage of time in a 10 minute cycle at which the welder can operate the machine at rated welding current Example 60 duty cycle Welding for 6 minutes Break for 4 minut...

Страница 11: ...ff the machine wait for a few seconds then turn ON again If the error remains a maintenance is required Please contact the nearest authorized technical service center or Lincoln Electric and report the error code read Steady Red Indicate no communication between the power source and device which has been connected to this power source 3 Thermal Overload Indicator It indicates that the machine is o...

Страница 12: ...ower source Insert the positive welding cable into the output socket 6 Insert the wire feeder control cable into the socket 7 see Accessories chapter Source wire feeder cable K10349 PG xM or K10349 PGW xM Use the shortest possible cable lengths Water Cooler Connection SPEEDTEC 405S 405SP 505S and 505SP work with the water cooler COOLARC 46 see Accessories chapter WARNING Read and understand the co...

Страница 13: ...tion indicator 3 will turn on The Power Source is also electronically protected against overload and accidental short circuit The overload and short circuit protection circuit automatically reduces the output current to a safe value when it detects an overload Transport Lifting WARNING Falling equipment can cause injury and damage to unit Figure 7 During transportation and lifting with a crane adh...

Страница 14: ... be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers ...

Страница 15: ... First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7440 43 9 Lead EC 231 ...

Страница 16: ...14072 1 LF45 Digital Wire Feeder K14083 1 LF45S Digital Wire Feeder K14106 1 PF40 Digital Wire Feeder K14107 1 PF42 Digital Wire Feeder K14108 1 PF44 Digital Wire Feeder K14109 1 PF46 Digital Wire Feeder K14110 1 PF24 Digital Wire Feeder K14121 1 Replaceable Front Panel with User Interface A K14122 1 Replaceable Front Panel with User Interface B K14123 1 Replaceable Front Panel with User Interface...

Отзывы: