Examine the brush holders:
The brush holder insulators must be clean and in good condition and all of the hardware must be in
. Replace any insulators that are cracked or damaged in any way.
When installing the brush holders, they should be rotated toward the brush retainer (clockwise
rotation when facing the brush holder mounting screw.) until they stop. The edge of the brush
holder plate should be parallel with the surface of the commutator and positioned .030 to .090 from
the surface of the commutator. The brush holder mounting screw should be tightened to a torque
of 24 to 28 Ft Lbs.
The brush holder plate and retainer assembly must be clean and smooth; nothing should prevent
free movement of the brushes. All electrical connections to the brush holders must be clean and
tight.
The recommended torque for 5/16-18 brush holder connection screws is 8 Ft.-Lbs.
8.
When testing is complete, attach the sheet metal cover protecting the welder generator brushes,
connect the negative battery terminal and close the left and right side covers.
Figure F.11 – Generator components
Содержание SAE-300 HE
Страница 8: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 3 Theory of Operation Figure F 1 Block Diagram ...
Страница 51: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 46 Figure F 13 Rocker w marks ...
Страница 54: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 49 Figure F 14 Brush spring Figure F 15 Windings insulated wedge ...
Страница 55: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 50 Figure F 1 Insulator spring locations Figure F 2 Shaft tube ...
Страница 64: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 59 Figure F 22 Rheostat terminal locations ...
Страница 68: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 63 Figure F 25 Rotor removal ...
Страница 75: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 70 Figure F 28 Sling lift ...
Страница 79: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 74 Figure F 30 Current sense board plug location ...
Страница 83: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 78 Figure F 32 Rheostat terminal locations ...