TROUBLESHOOTING

19

RANGER 8 LPG

TROUBLE

A.

No welder or output power.

B.

Engine will not idle down to
low speed.

C.

Engine will not go to high idle
when attempting to weld.

CAUSE

1.

Open in miscellaneous leads.

2.

Open lead in flashing or field
circuit.

3.

Faulty rotor.

4.

Faulty Potentiometer (R1).

5.

Faulty stator Field winding.

6.

Faulty Field rectifier (D2).

7.

Faulty P.C. Board.

1.

Idler switch on High Idle.

2.

Insufficient voltage present
between terminals #213 and
#5E.  (Voltage should be 12V
DC).

3.

External load on welder or
auxiliary power.

4.

Faulty wiring in solenoid circuit.

5.

Faulty idler solenoid.

6.

Faulty P.C. Board.

1.

Poor work lead connection to
work.

2.

No voltage signal from the
current sensor.

3.

No open circuit voltage on 
output studs.

4.

Faulty P.C. Board.

WHAT TO DO

1.

Refer to wiring diagram & 
check related leads.

2.

Refer to wiring diagram and
check all related leads (200,
224, 200A, 200B, 201, 201A).

3.

Lift brushes and check rotor
resistance between slip rings.
It should be approximately
4 ohms.

4.

Replace with known good one.

5.

Disconnect lead #9 at D2 and
check for continuity between
leads #9 and #7.

6.

Replace with known good one.

7.

Replace with known good one.

1.

Set switch on Automatic Idler.

2.

Check for proper connection of
leads (#213, #5E, #215, #209,
#209A, #224, #224A).

3.

Remove all external loads and
short circuits.

4.

Check for broken leads #213
and #215.

5.

Replace with known good one.

6.

Replace P.C. Board with 
known good one.

1.

Make certain work clamp is
tightly connected to clean base
metal.

2.

Check for disconnected or 
broken leads in idler sensing
circuit.

3.

Check generator output.

4.

Replace P.C. Board with
known good one.

Содержание RANGER 8 LPG

Страница 1: ...NUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful RANGER 8 LPG For Machines with Code Number 10526 10541 10937 IM604 B August 2002 R Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Prod...

Страница 2: ...R WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of Safety in Welding Cutting ANSI Standard Z49 1 from the American Welding Society P O Box 351040 Miami Florida 33135 or CSA Standard W117 2 1974 A Free copy of Arc Welding Safety booklet E205 is availa...

Страница 3: ...rical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders ...

Страница 4: ...event the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent hazardous situations Refer to Safety in Weldin...

Страница 5: ...s et non inflamma bles 4 Des gouttes de laitier en fusion sont émises de l arc de soudage Se protéger avec des vêtements de protection libres de l huile tels que les gants en cuir chemise épaisse pantalons sans revers et chaussures montantes 5 Toujours porter des lunettes de sécurité dans la zone de soudage Utiliser des lunettes avec écrans lateraux dans les zones où l on pique le laitier 6 Eloign...

Страница 6: ...where the information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes to the purchaser upon receipt by the carrier Consequently Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is ...

Страница 7: ...TIG Welding Applications 10 OPERATING INSTRUCTIONS 10 15 Additional Safety Precautions 10 Welder Operation 10 Welder Output 10 Ranger 8 Typical Fuel Consumption 10 Welder Controls Function and Operation 11 Start Shutdown Instructions 11 Break in Period 12 Welding Process 12 Stick Constant Current Welding 12 TIG Constant Current Welding 12 Wire Feed Welding Processes Constant Voltage 13 Summary of ...

Страница 8: ... Watt Incandescent Bulbs Can be Used for Standby Power OTHER FEATURES Polarity Switch for Selecting DC DC or AC Welding Output K930 1 TIG Module Available for high frequency and shielding gas control for AC and DC GTAW TIG welding applications Remote Control Receptacle Kit Available Electronic Engine Idler Engine Automatically Goes to Low Idle in 10 to 14 Seconds after Welding or Use of Auxiliary ...

Страница 9: ...115V 35 Amps 230V Dimensions Weight 30 3 x 19 2 x 43 8 in 770 x 488 x 1113 mm 511 lbs 233 kg Ranger 8 LPG Kohler SPECIFICATIONS Ranger 8 Kohler CH20S Command w LP 2 Cylinder 4 Cycle Air Cooled LPG Engine Aluminum Alloy with Cast Iron Liners Electronic Ignition Auto Electronic Idler Overhead Valves 20 HP 3600 RPM Full Load 3500 RPM High Idle 3700 RPM Low Idle 2200 RPM 38 1 cu in 624 cc Fuel LPG cyl...

Страница 10: ...150 200 250 0 10 20 30 40 50 60 70 80 DC STICK TIG CC OUTPUT OUTPUT AMPS OUTPUT VOLTS DC A 210 OUTPUT RANGE B 50 OUTPUT RANGE A B 0 50 100 150 200 250 300 350 0 10 20 30 40 50 60 70 80 CV OUTPUT RANGE 0 50 100 150 200 250 300 OUTPUT AMPS 350 0 5 10 15 20 25 30 35 40 DC WIRE FEED CV OUTPUT OUTPUT VOLTS DC SPECIFICATIONS ...

Страница 11: ...electrode cable 25 ft 7 6m 3 AWG work cable headshield with No 12 filter GC300 work clamp and Cooltong 300 electrode holder Cables are rated at 225 amps 40 duty cycle Remote Control Receptacle Kit K892 1 Includes a 6 pin MS type Amphenol receptacle and a local remote toggle switch that mounts in the case front Requires a Remote Control Option Remote Control K857 Consists of a control box with 25 f...

Страница 12: ...al TIG Module Docking Kit K939 1 Arc Start Switch K1814 Hand Amptrol K963 Foot Amptrol K870 Remote Control Receptacle Kit K892 1 WIRE FEED LN 25 K449 Includes internal contactor for across the arc operation no control cable Provides cold electrode until gun trigger is pressed Includes gas solenoid Remote control Receptacle Kit K892 1 and Remote Voltage Control Kit K444 1 are required for voltage c...

Страница 13: ...d with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard The standard muffler included with this welder does not qualify as a spark arrester When required by local regulations the K894 1 spark arrester must be installed and properly maintained An incorrect arrester may lead to damage to the engine or adversely affect performance T...

Страница 14: ...T Specification 4E 240 The valve on the fuel cylinder must be installed on the outlet marked LIQUID The engine will not develop full power if connected to the vapor outlet Be certain that the cylinder valve is CLOSED before attempting to attach the fuel supply hose coupler to the cylinder Connect the coupler to the fuel cylinder and tighten by hand ___________________________________________ After...

Страница 15: ...e connections should be checked periodically and tightened if neces sary Loose connections will result in overheating of the output studs When welding at a considerable distance from the welder be sure you use ample size welding cables Listed below are copper cable sizes recommended for the rated current and duty cycle Lengths stipulated are the distance from the welder to work and back to the wel...

Страница 16: ...provide an unrestrict ed flow of clean cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet Connection of Lincoln Electric Wire Feeders Shut off welder before making any electrical connections Wire Feed Constant voltage Connection of the LN 25 to the Ranger 8 a Shut the welder off b Connect the electrode cable from the LN 2...

Страница 17: ...tor Order Kit T12246 must be installed in the Ranger 8 OPERATING INSTRUCTIONS Additional Safety Precautions Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow Do not tamper with the carburetor settings or the fuel hose from the regulator to the carburetor The engine has been pre set for optimum p...

Страница 18: ...ne has started slowly return the choke control to the full in position Choke Open Do not touch electrically live parts of electrode with skin or wet clothing Keep flammable material away Insulate yourself from work and ground Wear eye ear and body protection Keep your head out of the fumes Use ventilation or exhaust to remove fumes from breathing zone WARNING 11 11 RANGER 8 LPG Welder Controls Fun...

Страница 19: ... the Polarity switch to the desired polarity Set the RANGE switch to a setting that is equal to or slightly greater than the desired welding current The RANGE dial marking indicates the maximum current for that range Fine adjustment of the welding current is made by adjusting the output CONTROL or remote control For best arc stability use settings 5 through 10 The Ranger 8 can be used with a broad...

Страница 20: ... WIRE FEED LN 25 WITH No AUTO Cold Press gun trigger LN 25 INTERNAL CONTACTOR contactor closes Welding starts immediately and engine goes to high idle NOTE Output Control must be set above 3 WIRE FEED LN 7 WITH Yes HIGH Cold Press gun trigger K240 CONTACTOR KIT contactor closes Welding starts immediately It is recommended that the Ranger 8 be used in HIGH idle when using the TIG Module It can be u...

Страница 21: ...rough 2 hp can be run pro vided the receptacle rating as previously stated is not exceeded This may necessitate 230V operation only Auxiliary Power While Welding It must be noted that the above auxiliary power ratings are with no welding load Simultaneous welding and power loads are permitted by following Table I The permissible currents shown assume that current is being drawn from either the 115...

Страница 22: ...ired length The 50 amp 115 230V plug is available in the optional plug kit 4 Plug this cable into the 50 amp 115 230V receptacle on the Ranger 8 case front Figure 1 CONNECTION OF RANGER 8 TO PREMISES WIRING 230 Volt 60 Hz 3 Wire Service POWER COMPANY METER 230 VOLT 115 VOLT 115 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE No 8 COPPER CONDUCTOR CA...

Страница 23: ... loading is recom mended for 100 fail safe operation DO NOT RUN THESE DEVICES WITHOUT ADDITIONAL RESISTIVE TYPE LOADS Inductive Single phase induction motors These devices may require large drills well pumps grinders small current inrush for starting refrigerators weed and hedge trimmers Some synchronous motors may be frequency sensitive to attain maximum output torque but they SHOULD BE SAFE from...

Страница 24: ...r to the maintenance section of the Engine Owner s Manual for more information NOTE Engine life will be reduced if the oil and oil filter are not changed according to the manufacturer s recommendation 3 Air Cleaner With normal operating conditions the maintenance schedule for cleaning and re oil ing the foam pre filter is every 25 hours and replacement of the air cleaner filter every 100 hours Mor...

Страница 25: ...r CHAMPION RC12YC Type 030 GAP GASES FROM BATTERY can explode Keep sparks flame and cigarettes away from battery To prevent EXPLOSION when INSTALLING A NEW BATTERY disconnect negative cable from old battery first and connect to new battery last CONNECTING A BATTERY CHARGER Remove bat tery from welder by disconnecting negative cable first then positive cable and battery clamp When rein stalling con...

Страница 26: ...rcuit voltage on output studs 4 Faulty P C Board WHAT TO DO 1 Refer to wiring diagram check related leads 2 Refer to wiring diagram and check all related leads 200 224 200A 200B 201 201A 3 Lift brushes and check rotor resistance between slip rings It should be approximately 4 ohms 4 Replace with known good one 5 Disconnect lead 9 at D2 and check for continuity between leads 9 and 7 6 Replace with ...

Страница 27: ... Low oil level 1 Air filter clogged 1 Spark plugs do not have specified gap 2 Spark plugs are fouled WHAT TO DO 1 Check for disconnected or broken leads in idler sensing circuit 2 Idler may not function with less than 100 to 150 watt load Set idler switch to high idle 3 Replace P C Board with known good one 1 Replace with known good one 2 Check the connection of the lead from the voltage regulator...

Страница 28: ...OSS SUPPORT GROUND SCREW GND E GND E GND G 200B 219 201A 224 215 76 5E 75 77 J1 8 10 5D 7 254A 254 254 254A B 254A R1 OUTPUT CONTROL 75A 76A 77A 1 3 2 4 P5 J5 75A 77A 76A FIELD CAPACITOR AT BLOWER BAFFLE 209 211 U BLUE V VIOLET R R U V W ENGINE FOOT GND D GND C 5F 224A GND H TERMINALS 6 5 5L 115V 230V 5K GND D GND C J4 J3 J2 GND G 5 5L 5K 115V 115V 12 11 11 3E 3E 3C 3A 3A 3B 3B 3D 3D CB1 35A 35A C...

Страница 29: ... 76 5E 75 77 J1 8 10 5D 7 254 B R1 OUTPUT CONTROL 75A 76A 77A 1 3 2 4 P5 J5 75A 77A 76A FIELD CAPACITOR AT BLOWER BAFFLE 209 211 R R U V W ENGINE FOOT GND D GND C 5F 224A GND H TERMINALS 6 5 5L 115V 230V 5K GND D GND C J4 J3 J2 GND G 5 5L 5K 115V 115V 12 11 11 3B 3B 3A 3A CB1 35A 35A CB2 CB3 20A 20A CB4 3 221 CAVITY 1 SILVER COLORED WHITE WIRES A CCW ALL CASE FRONT COMPONENTS SHOWN VIEWED FROM REA...

Страница 30: ...rpose Connect it directly to the work piece independent of the welding work cable For conve nience this extended 21 lead should be taped to the welding work lead N G Tape up bolted connection where lead 21 is extended N H Idler switch on power source must be in high idle position N J If an optional remote output control is used connect it to this terminal strip or 6 pin Amphenol receptacle NOTE Te...

Страница 31: ...1 9 31 M17215 4 CRM28731 9 09 9 09 UNDERCARRIAGE MOUNTING HOLES 42 25 42 00 CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK 11 31 FOR OIL FILTER REMOVAL 8 80 30 00 2 75 24 DIMENSION PRINT 24 RANGER 8 LPG DIMENSION PRINT Ranger 8 LPG Kohler ...

Страница 32: ...NOTES RANGER 8 LPG ...

Страница 33: ...NOTES RANGER 8 LPG ...

Страница 34: ...NOTES RANGER 8 LPG ...

Страница 35: ...TOTAL COST Now Available 12th Edition The Procedure Handbook of Arc Welding With over 500 000 copies of previous editions published since 1933 the Procedure Handbook is considered by many to be the Bible of the arc welding industry This printing will go fast so don t delay Place your order now using the coupon below The hardbound book contains over 750 pages of welding information techniques and p...

Страница 36: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y de la tierra Ne laissez ni la peau ni des vête ments mouillés entrer en contact avec des pièces sous tension Isolez vous du travail et de la terre Berühren Sie keine stromführenden Teile oder Elektrode...

Страница 37: ...gute Be und Entlüftung des Arbeitsplatzes Mantenha seu rosto da fumaça Use ventilação e exhaustão para remover fumo da zona respiratória Turn power off before servicing Desconectar el cable de ali mentación de poder de la máquina antes de iniciar cualquier servicio Débranchez le courant avant l entre tien Strom vor Wartungsarbeiten abschalten Netzstrom völlig öff nen Maschine anhalten Não opere co...

Страница 38: ...s and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Products ...

Отзывы: