B-6
OPERATION
RANGER
®
260MPX & 330MPX
WELD SCREENS, READY.SET.WELD.
?
Press knob for options
Output
ON
92
A
F
E
½
Ready.Set.Weld. recommends ranges for a given weld
procedure. To start the Ready.Set.Weld, press the Help button
when in a preset welding screen.
Rotate the knob to choose the electrode type.
Press the knob to select. To turn off
Ready.Set.Weld, select “Manual Entry”.
?
Press knob to select
Electrode Type
6010
6013
Output
OFF
Manual Entry
Next, select the electrode diameter. Press the knob
to select
?
Press knob to select
Electrode Diameter
1/8”
Output
OFF
?
16 Ga
Press knob to select
7018
1/8
Select the material thickness.
Press the knob to select.
Connect the electrode and work cables as shown in the
diagram. When complete, press the knob to turn the
output ON and start welding.
?
Output
OFF
Press knob to turn output on
7018
1/8
18 Ga.
DC+
7018
Содержание Ranger 260MPX
Страница 54: ...This page intentionally left blank ...
Страница 55: ...This page intentionally left blank ...