RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode
No Load RPM
Load RPM
Low Idle
2350 - 2450
N/A
High Idle
3700 - 3750
3350 - 3580
WELDER DC (STICK) OUTPUT (ARC control @ -10)
Mode Selector
Output Control
Open Circuit
Load Volts
Load Amps
Switch
Volts
Stick (CC)
Maximum
74-79
25-30
245-265
WELDER CV (WIRE) OUTPUT (ARC Control @ +10)
Mode Selector
Output Control
Open Circuit
Load Volts
Load Amps
Switch
Voltage
CV
Maximum
56-64
25-30
245-265
CV
Minimum
20-28
13-14.5
25-30
TOUCH START TIG (ARC Control @ +10)
Mode Selector
Output Control
Open Circuit
Load Volts
Load Amps
Switch
Voltage
TIG
Maximum
16-19
25-30
245-265
TIG
Minimum
16-19
Short Circuit
19-24
AUXILIARY POWER OUTPUT
240 Volt Receptacle
120 Volt Receptacles
Open Circuit
Load Volts
Load Amps
Open Circuit
Load Volts
Load Amps
Voltage
Voltage
236-252
216-225
35-39
118-126
110-120
18-22
42 VOLT WIRE FEEDER POWER
Open Circuit Voltage
Load Volts
Load Amps
42-46
40-44
7.0-9.0
Retur