[ 4 ]
|
Ranger
®
225
MACHINE SPECIFICATIONS
Product
Name
Ordering
Information
Description
CC Rated Output
Current/Voltage/Duty
Cycle
CV-Rated Output
Current/Voltage/Duty
Cycle
Generator
AC Power
(2)(3)
Dimension
H x W x L
inches (mm)
Weight
lbs. (kg)
Ranger
®
225
(Kohler
®
OHV)
K2857-1
225 Amp DC
Arc Welder
10,500 Watts Peak
9,000 Watts Continuous
AC Power
DC Constant Current
225A/25V/40%
210A/25V/100%
Current Ranges
120-225A
70-145A
50-90A
Max OCV @ 3700 RPM
80V RMS
DC Constant Voltage
(1)
200A/20V/100%
15-25V
10,500
Watts Peak
9,000 Watts Continuous
60 Hz Single Phase
Two 120V Duplex
Receptacles
20A per Duplex
40A Total
(4)
120V/240V
Receptacle
38A Each
120V Branch
(4)
38A @ 240V
29.9 x 21.5 x 42.3
(759 x 546 x 1074)
To top of exhaust tube:
36.2 (920)
514
(233)
(1)
DC constant voltage capability provides convenience and added safety when welding in electrically hazardous conditions.
(2)
When welding, available auxiliary power will be reduced. Output voltage is \- 10% at all loads up to rated capacity.
(3)
120V will operate either 60 Hz or 50/60 Hz power tools, lights, etc.
(4)
Circuits cannot be wired in parallel to operate the same device.
ENGINE SPECIFICATIONS
Engine
Model
Description
Horsepower &
Displacement
Ignition
Capacities
Operating
Speeds
Fuel
Consumption
Kohler
®
OHV
(5)
Command CH23S
(Gasoline)
2 Cylinder, 4 Cycle,
OHV Air-Cooled
Gasoline Engine
Aluminum Alloy with
Cast Iron Liners
23 HP @ 3600 RPM
41.0 cu in
(674 cc)
Electric Start
12V Battery
435 Cold Cranking Amps
Manual Choke
FUEL:
12 Gals (45 Ltrs)
OIL:
2.0 Qts (1.9 Ltrs)
210A DC
3,500 RPM
High Idle
3,700 RPM
Low Idle
2,200 RPM
1.3 Gals/Hr
4.9 Ltr/Hr
0.7 Gals/Hr
2.8 Ltr/Hr
0.4 Gals/Hr
1.5 Ltr/Hr
(5)
Kohler
®
warranty is 3 years.
A Ranger
®
225 is an excellent choice for a wide variety of projects.