INSTALLATION   

WELDMARK  225

A-4

TOWING

The recommended trailer for use with this equipment for road,
in-plant and yard towing by a vehicle

(1)

is Lincoln’s K957-1. If

the user adapts a non-Lincoln trailer, he must assume responsi-
bility that the method of attachment and usage does not result
in a safety hazard nor damage the welding equipment. Some of
the factors to be considered are as follows:

1.  Design capacity of trailer vs. weight of Lincoln equipment

and likely additional attachments. 

2.  Proper support of, and attachment to, the base of the weld-

ing equipment so there will be no undue stress to the frame-
work.

3.  Proper placement of the equipment on the trailer to insure

stability side to side and front to back when being moved
and when standing by itself while being operated or ser-
viced.

4.  Typical conditions of use, i.e., travel speed; roughness of

surface on which the trailer will be operated; environmental
conditions; like maintenance.

5.  Conformance with federal, state and local laws.

(1)

(1)

Consult applicable federal, state and local laws regarding
specific requirements for use on public highways.

PRE-OPERATION SERVICE

READ the engine operating and maintenance instruc-
tions supplied with this machine.

OIL

The Weldmark 225 is shipped with the engine crankcase
filled with SAE 10W-30 oil. Check the oil level before
starting the engine. If it is not up to the full mark on the
dip stick, add oil as required. Make certain that the oil
filler cap is tightened securely. Refer to the engine
Owner’s Manual for specific oil recommendations.

FUEL

Fill the fuel tank with clean, fresh, lead-free gasoline.
Observe fuel gauge while filling to prevent overfilling.

BATTERY CONNECTIONS

This welder is shipped with the negative battery cable
disconnected.  Make sure that the Engine Switch is in the
“STOP” position and attach the disconnected cable
securely to the negative battery terminal before attempt-
ing to operate the machine. If the battery is discharged
and does not have enough power to start the engine, see
the battery charging instructions in the Battery section.

WELDING OUTPUT CABLES

With the engine off, connect the electrode and work
cables to the studs provided. These connections should
be checked periodically and tightened if necessary.
Loose connections will result in overheating of the output
studs.

When welding at a considerable distance from the
welder, be sure you use ample size welding cables.
Listed below are copper cable sizes recommended for
the rated current and duty cycle. Lengths stipulated are
the distance from the welder to work and back to the
welder again. Cable sizes are increased for greater
lengths primarily for the purpose of minimizing cable volt-
age drop.

TOTAL COMBINED  LENGTH  OF

ELECTRODE  AND  WORK  CABLES

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-250 Ft.

225 Amps

40% Duty Cycle

3 AWG

3 AWG

2 AWG

1 AWG

1/0 AWG

225 Amps

100% Duty Cycle

1 AWG

1 AWG

1 AWG

1 AWG

1/0 AWG

LUBRICATION SYSTEM CAPACITY

(INCLUDING FILTER)

Kohler CH20S - 2.0 Quarts (1.9 Liters)

• Stop engine while fueling.
• Do not smoke when fueling.
• Keep sparks and flame away

from tank.

• Do not leave unattended while

fueling.

• Wipe up spilled fuel and allow

fumes to clear before starting
engine.

• Do not overfill tank, fuel expan-

sion may cause overflow.

GASOLINE FUEL ONLY

------------------------------------------------------------------------

WARNING

GASOLINE

can cause fire
or explosion.

VEHICLE MOUNTING

Improperly mounted concentrated loads may
cause unstable vehicle handling and tires or other
components to fail.

 Only transport this Equipment on serviceable

vehicles which are rated and designed for such
loads.

 Distribute, balance and secure loads so vehicle

is stable under conditions of use.

 Do not exceed maximum rated loads for compo-

nents such as suspension, axles and tires.

 Use appropriate nuts bolts and lockwashers to

attach the equipment base to the metal bed or
frame of vehicle.

 Follow vehicle manufacturer

s instructions.

------------------------------------------------------------------------

CAUTION

Содержание RANGER 225 GXT

Страница 1: ... INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful R Manufactured by Lincoln Electric Company Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com Copyright 2005 Lincoln Global Inc This manual covers equipment which is no longer i...

Страница 2: ...R WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of Safety in Welding Cutting ANSI Standard Z49 1 from the American Welding Society P O Box 351040 Miami Florida 33135 or CSA Standard W117 2 1974 A Free copy of Arc Welding Safety booklet E205 is availa...

Страница 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders 3...

Страница 4: ...event the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent hazardous situations Refer to Safety in Weldin...

Страница 5: ...s et non inflammables 4 Des gouttes de laitier en fusion sont émises de l arc de soudage Se protéger avec des vêtements de protection libres de l huile tels que les gants en cuir chemise épaisse pan talons sans revers et chaussures montantes 5 Toujours porter des lunettes de sécurité dans la zone de soudage Utiliser des lunettes avec écrans lateraux dans les zones où l on pique le laitier 6 Eloign...

Страница 6: ... followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes to the purchaser upon receipt by the carrier Consequently Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received Please record your e...

Страница 7: ...Starting the Engine B 3 Safety Precautions B 3 Stopping the Engine B 3 Break In Period B 3 Welding Process B 4 Duty Cycle B 4 Stick Constant Current Welding B 4 TIG Constant Current Welding B 4 DC Wire Feed Welding Processes CV B 4 Summary of Welding Processes B 5 _________________________________________________________________________________________ Accessories Section C General Options Accesso...

Страница 8: ...nstant Current 225A 25V 100 DC Constant Current 210A 25V 100 DC Constant Voltage 200A 20V 100 Auxiliary Power 8 000 Watts 60 Hz AC 70 Amps 115V 35 Amps 230V PHYSICAL DIMENSIONS Make Model Kohler CH20S Description 2 cylinder 4 Cycle Air Cooled Gasoline Engine Aluminum Alloy with Cast Iron Liners Electrical Ignition Speed RPM High Idle 3700 Full Load 3500 Low Idle 2200 Displacement cu in cu cm 38 62...

Страница 9: ...0 100 150 200 250 0 10 20 30 40 50 60 70 80 DC STICK TIG CC OUTPUT OUTPUT AMPS OUTPUT VOLTS DC RMS A 210 OUTPUT RANGE B 50 OUTPUT RANGE A B 0 50 100 150 200 250 300 350 0 10 20 30 40 50 60 70 80 CV OUTPUT RANGE 0 50 100 150 200 250 300 OUTPUT AMPS 350 0 5 10 15 20 25 30 35 40 DC WIRE FEED CV OUTPUT OUTPUT VOLTS DC RMS SPECIFICATIONS ...

Страница 10: ...s provided on the front of the welder SPARK ARRESTER Some federal state or local laws may require that gasoline engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard The standard muffler included with this welder does not qualify as a spark arrester When required by local regulations the K894 1 spark arrester ...

Страница 11: ...cted cable securely to the negative battery terminal before attempt ing to operate the machine If the battery is discharged and does not have enough power to start the engine see the battery charging instructions in the Battery section WELDING OUTPUT CABLES With the engine off connect the electrode and work cables to the studs provided These connections should be checked periodically and tightened...

Страница 12: ...allow muffler to cool before touching muffler The Weldmark 225 is shipped with the exhaust com ing out on the left side The exhaust can be changed to the opposite side by removing the two screws that hold the exhaust port cover in place and installing the cover on the opposite side Operating the Weldmark 225 without the cover in place will result in a higher noise level and no increase in machine ...

Страница 13: ...her safety procedures included in this manual and in the Engine Owner s Manual WELDER OPERATION WELDER OUTPUT Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS Duty Cycle 100 for both welding and auxiliary power AUXILIARY POWER Start the engine and set the IDLER control switch to the High Idle mode Voltage is now correct at the receptacles for auxiliary power This must be done before a trip...

Страница 14: ...GFCI duplex Receptacles No Welding NEMA 5 20P Plug required for 20Amp Draw MOTOR STARTING Most 1 5 hp AC single phase motors can be started if there is no load on the motor or other load connected to the machine since the full load current rating of a 1 5 hp motor is approximately 20 amperes 10 amperes for 230 volt motors The motor may be run at full load when plugged into only one side of the dup...

Страница 15: ...ESE DEVICES WITHOUT ADDITIONAL RESISTIVE TYPE LOADS Inductive Single phase induction motors These devices require large drills well pumps grinders small current inrush for starting refrigerators weed and hedge Some synchronous motors may trimmers be frequency sensitive to attain maximum output torque but they SHOULD BE SAFE from any frequency induced failures Capacitive Inductive Computers high re...

Страница 16: ...educe output voltage below the allowable 10 of rated voltage which may damage appliances or other motor driven equipment 3 Install a 50 amp 115 230V plug NEMA type 14 50 to the Double Pole Circuit Breaker using No 8 4 conductor cable of the desired length The 50 amp 115 230V plug is available in the optional plug kit 4 Plug this cable into the 50 amp 115 230V receptacle on the Weldmark 225 case fr...

Страница 17: ...EUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE No 8 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS 230 VOLT GROUNDED CONDUCTOR 35AMP 230 VOLT DOUBLE POLE CIRCUIT BREAKER DOUBLE POLE DOUBLE THROW SWITCH RATING TO BE THE SAME AS OR GREATER THAN PREMISES SERVICE OVERCURRENT PROTECTION 50 AMP 115 230 VOLT PLUG NEMA TYPE ...

Страница 18: ...or If Started Under No Load Lights Eighty 100 Watt Incandescent Bulbs Can be Used for Standby Power OTHER FEATURES Bottom Mounted 9 Gallon Fuel Tank with a Convenient Top Fill and Fuel Gauge Polarity Switch for Selecting DC DC or AC Welding Output K930 1 TIG Module Available Remote Control Receptacle Kit Available Electronic Engine Idler Engine Automatically Goes to Low Idle in 10 to 14 Seconds af...

Страница 19: ...is being drawn the engine will return to low idle after approximately 10 to 14 seconds Auxiliary Power With the engine running at low idle and auxiliary power for lights or tools is drawn approximately 100 150 watts or greater from the receptacles the engine will accelerate to high speed If no power is being drawn from the receptacles and not welding for 10 14 seconds the idler reduces the engine ...

Страница 20: ... auxiliary power loads and allow engine to run at low idle speed for a few minutes to cool the engine Stop the engine by placing the Engine switch in the OFF position A fuel shut off valve is not required on the WELD MARK 225 because the fuel tank is mounted below the engine BREAK IN PERIOD It is normal for any engine to use a greater amount of oil until the break in is accomplished Check the oil ...

Страница 21: ...and electrodes are recommended The K930 TIG Module should be used with the Weldmark 225 on high idle to maintain satisfactory operation It can be used in the AUTO position but the delay going to flow idle after welding is ceased will be increased if the AFTERFLOW CONTROL is set above 10 seconds WIRE FEED WELDING PROCESSES CONSTANT VOLTAGE The only Innershield electrode recommended for use with the...

Страница 22: ...high idle TIG K7930 1 K938 1 Yes HIGH Cold Press Amptrol contactor K936 K892 1 closes welding WITH AMPTROL starts immediately WIRE FEED LN 25 WITH No AUTO Cold Press gun trigger LN 25 INTERNAL CONTACTOR contactor closes Welding starts immediately and engine goes to high idle NOTE Output Control must be set above 3 WIRE FEED LN 7 WITH Yes HIGH Cold Press gun trigger K240 CONTACTOR KIT contactor clo...

Страница 23: ...es with GFCI recep tacles use K802 R K704 Accessory Kit Includes 35 ft 10 7m 2 0 AWG elec trode cable 30 ft 9 1m 2 0 AWG work cable headshield with No 12 filter GC300 work clamp and Cooltong 300 electrode holder Cables are rated at 300 amps 100 duty cycle K892 1 Remote Control Receptacle Kit Includes a 6 pin MS type Amphenol receptacle and a local remote toggle switch that mounts in the case front...

Страница 24: ...le see Optional Equipment Optional K939 1 Docking Kit K963 Hand Amptrol K870 Foot Amptrol K892 1 Remote Control Receptacle Kit K915 1 Adapter Cable WIRE FEED K449 LN 25 Includes internal contactor for across the arc operation no control cable Provides cold electrode until gun trigger is pressed Includes gas solenoid K892 1 Remote control Receptacle Kit and K444 1 Remote voltage Control Kit are req...

Страница 25: ...or normal operating condi tions More frequent oil changes are required with dusty high temperature and other severe operating conditions Refer to the maintenance section of the Engine Owner s Manual for more information NOTE Engine life will be reduced if the oil and oil filter are not changed according to the manufacturer s recommendation ENGINE OIL CHANGE Drain the oil while the engine is warm t...

Страница 26: ...se then use an oil fil ter socket tool to tighten the filter an additional 1 2 to 7 8 turn Refill the crankcase with the specified amount of the recommended oil Reinstall the oil filler cap Start the engine and check for oil filter leaks Stop the engine and check the oil level If neces sary add oil to the upper limit mark on the dipstick Air Cleaner With normal operating conditions the maintenance...

Страница 27: ...ositive battery cable before attaching the charger leads Failure to do so can result in damage to the internal charger components When reconnecting the cables connect the positive cable first and the negative cable last HARDWARE Both English and Metric fasteners are used in this welder WELDMARK 225 WARNING GASES FROM BATTERY can explode Keep sparks flame and cigarettes away from battery To prevent...

Страница 28: ...ker for this receptacle must not be tripped Reset if necessary Push the Reset button located on the GFCI recep tacle This will assure normal GFCI operation Plug a night light with an ON OFF switch or other product such as a lamp into the GFCI receptacle and turn the product ON Push the Test button located on the GFCI recepta cle The night light or other product should go OFF Push the Reset button ...

Страница 29: ...abeled POSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause generally it states to contact your local Authorized Field Service Facility If you do not understand or are unable to perform the Recommended Course of Action safely contact your local Authorized...

Страница 30: ... 1 Open in miscellaneous leads 2 Open lead in flashing or field circuit 3 Faulty rotor 4 Faulty Potentiometer R1 5 Faulty stator Field winding 6 Faulty Field rectifier D2 7 Faulty P C Board 1 Idler switch on High Idle 2 Insufficient voltage present between terminals 213 and 5E Voltage should be 12V DC 3 External load on welder or auxiliary power 4 Faulty wiring in solenoid circuit 5 Faulty idler s...

Страница 31: ...start No auxiliary power 1 No voltage signal from the current sensor 2 Auxiliary power load less than 100 to 150 watts 3 Faulty P C Board 1 Battery will not hold a charge Faulty Battery 2 No or insufficient charging current 3 Loose battery cable connection s 1 Out of fuel 2 Low oil level 1 Fuel filter clogged 2 Air filter clogged 1 Spark plugs do not have specified gap 2 Spark plugs are fouled 1 G...

Страница 32: ...Y 4 1 3 2 4 211 IGNITION MODULE 221 B 5H M20049 215 ELECTRICAL SYMBOLS PER E1537 STATOR REACTOR S1 WORK ELECTRODE CHOKE D1 S2 D2 ROTOR C1 PCB1 SLIP RING NEAREST LAMINATION W1 W2 C1 S1 E R1 R2 R4 R5 R6 C1 S2 L1 R3 STATOR REACTOR 2 10 8 1 7 12 6 6 5 3 9 9 7 200A 200 201A 201 219 200B 3 ENGINE CROSS SUPPORT GROUND SCREW GND E GND E GND G 200B 219 201A 224 215 76 5E 75 77 J1 8 10 5D 7 254 B R1 OUTPUT ...

Страница 33: ...e Connect it directly to the work piece independent of the welding work cable For convenience this extended 21 lead should be taped to the welding work lead N G Tape up bolted connection where lead 21 is extended N H Idler switch on power source must be in high idle position N J If an optional remote output control is used connect it to this terminal strip or 6 pin Amphenol receptacle NOTE Termina...

Страница 34: ... OF SHAFT 9 29 21 21 9 31 2 75 17 00 26 59 19 11 30 28 9 09 9 09 UNDERCARRIAGE MOUNTING HOLES 42 25 CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK 11 31 21 95 FOR OIL FILTER REMOVAL 30 00 8 80 30 00 42 00 C M17215 2 1 30 98E ...

Страница 35: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y de la tierra Ne laissez ni la peau ni des vête ments mouillés entrer en contact avec des pièces sous tension Isolez vous du travail et de la terre Berühren Sie keine stromführenden Teile oder Elektrode...

Страница 36: ...gute Be und Entlüftung des Arbeitsplatzes Mantenha seu rosto da fumaça Use ventilação e exhaustão para remover fumo da zona respiratória Turn power off before servicing Desconectar el cable de ali mentación de poder de la máquina antes de iniciar cualquier servicio Débranchez le courant avant l entre tien Strom vor Wartungsarbeiten abschalten Netzstrom völlig öff nen Maschine anhalten Não opere co...

Страница 37: ... Manufactured by Lincoln Electric Company Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com ...

Отзывы: