CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Wire burns back to tip at the end of the
weld.
Machine output shuts down during a weld.
Machine won’t produce full output.
Excessively long and erratic arc.
1. Burnback Time
1. Secondary current limit has been exceed-
ed, and the machine shuts down to pro-
tect itself.
2. System Fault
1. Input voltage may be too low, limiting
output capability of the power source.
2. The input may be single phase.
3. Machine calibration.
1. Wire feed problem.
2. Loss of, or improper Shielding Gas
3. Machine calibration.
1. Reduce burnback time and/or work point.
1. Adjust procedure or reduce load to lower
current draw from the machine.
2. A non-recoverable fault will interrupt
welding. This condition will also result in
a status light blinking. See the Status
Light section for more information.
1. Make certain that the input voltage is
proper, according to the Rating Plate
located on the rear of the machine.
2. Verify all 3 phases are present.
3. Calibrate secondary current and voltage.
1. Check for feeding problems. Make sure
proper gear ratio has been selected.
2. Verify gas flow and type are correct
3. Calibrate secondary current and voltage.
Weld and Arc Quality Problems (Continued)
E-7
TROUBLESHOOTING
POWER WAVE
®
R500
Содержание POWER WAVE R500
Страница 36: ...F 2 DIAGRAMS POWER WAVE R500 L16215 A 01 13 94 22 45 27 43 6 00 18 35 24 76...
Страница 37: ...F 3 NOTES...
Страница 38: ...F 4 NOTES...
Страница 39: ...F 5 NOTES...
Страница 44: ...P 885 C jpg Case Front Assembly Power Wave R500 12483 5 Printed 10 02 2015 at 08 39 52 Produced by Enigma...
Страница 50: ...P 885 E jpg Case Back Assembly Power Wave R500 12483 11 Printed 10 02 2015 at 08 39 52 Produced by Enigma...
Страница 53: ...P 885 F jpg Roof Assembly 14 Power Wave R500 12483 Printed 10 02 2015 at 08 39 52 Produced by Enigma...