PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
F
-4
TROUBLESHOOTING
POWER MIG
®
360MP
The wire feed stops while welding. When
trigger is released and pulled again the
wire feed starts.
1. Check the wire feed drive rolls and motor
for smooth operation.
2. Check for restrictions in the wire feed
path.
3. Make sure gun liner and tip are correct
for wire size being used.
4. Check spindle for ease of rotation.
5. Make sure drive rolls and guide plates
are clean and the correct size.
No control of wire feed speed. Other
machine functions are normal.
1. The wire feed speed control may be
dirty. Rotate several times and check if
problem is resolved.
GAS FLOW PROBLEMS
Gas does not flow when gun trigger is
pulled.
1. Make sure gas supply is connected
properly and turned “ON”.
If all recommended possible areas of
misadjustment have been checked and the
problem persists, Contact your local Lincoln
Authorized Field Service Facility.
2. If the gas solenoid does not actuate
(click) when the gun trigger is pulled,
there may be a restriction in the gas
supply line.
3. The gun cable assembly may be faulty.
Check or replace.
4. If gas solenoid does not operate when
gun trigger is pulled, the problem is
within the POWER MIG
®
360MP.
5. Make sure the gun is pushed all the way
into gun mount and is properly seated.
SCREEN PROBLEMS
Error code 213 is displayed on screen
1. Communication between display P.C.
board and power control board.
1. Cycle power to machine.
ERROR CODE 36, Thermal trip
1. Machine is overloaded
1. Welding duty should not exceed machine
rating
2. Poor airflow
2. Not enough space behind the back of the
machine
ERROR CODE 81, Main motor overload
1. Drive rolls don’t match wire size or wire
type
1. Check drive rolls
2. Bad gun liner
2. Try different gun
ERROR 95, Gun motor overload
1. Drive rolls don’t match wire size or wire
type
1. Check drive rolls
2. Bad gun liner
2. Try different gun
ERROR CODE 213, Control board offline
No communication between UI & Control PCB
1. Check UI & Control board connection
2. Replace Control PCB
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Содержание Power MIG 360MP
Страница 38: ...G 2 DIAGRAMS POWER MIG 360 Center of Gravity 12 38 37 38 40 35 13 33 37 30 18 00 16 88 11 62 ...
Страница 39: ...This page has been left blank intentionally ...
Страница 40: ...This page has been left blank intentionally ...
Страница 41: ...This page has been left blank intentionally ...