FOR ELECTRICALLY
powered equipment.

8.a. Turn off input power using the disconnect

switch at the fuse box before working on
the equipment.

8.b. Install equipment in accordance with the U.S. National

Electrical Code, all local codes and the manufacturer’s
recommendations.

8.c. Ground the equipment in accordance with the U.S. National

Electrical Code and the manufacturer’s recommendations.

CYLINDER may explode
if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely

chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

• Away from areas where they may be struck or subjected to

physical damage.

• A safe distance from arc welding or cutting operations and

any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other

electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet

when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand

tight except when the cylinder is in use or connected for
use.

7.g. Read and follow the instructions on compressed gas

cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.

iii

SAFETY

iii

Mar ‘95

WELDING SPARKS can
cause fire or explosion.

6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to prevent

the welding sparks from starting a fire.
Remember that welding sparks and hot

materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,

special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.

6.c. When not welding, make certain no part of the electrode

circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the

proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even though they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).

6.e. Vent hollow castings or containers before heating, cutting or

welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil

free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.

6.g. Connect the work cable to the work as close to the welding

area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.

6.h. Also see item 1.c.

Содержание Power Feed 10 Robotic K1780-2

Страница 1: ...NSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful For use with machines having code numbers 10944 11301 Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s ...

Страница 2: ...R WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of Safety in Welding Cutting ANSI Standard Z49 1 from the American Welding Society P O Box 351040 Miami Florida 33135 or CSA Standard W117 2 1974 A Free copy of Arc Welding Safety booklet E205 is availa...

Страница 3: ...ter for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders 3 i When working above floor level use a safety belt to protect yourself from a fall should you get a shock 3 j Also see Items 6 c and 8 FUMES AND GASES can be dangerous 5 a Welding may produ...

Страница 4: ...event the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent hazardous situations Refer to Safety in Weldin...

Страница 5: ...propriés et non inflammables 4 Des gouttes de laitier en fusion sont émises de l arc de soudage Se protéger avec des vêtements de protection libres de l huile tels que les gants en cuir chemise épaisse pan talons sans revers et chaussures montantes 5 Toujours porter des lunettes de sécurité dans la zone de soudage Utiliser des lunettes avec écrans lateraux dans les zones où l on pique le laitier 6...

Страница 6: ...tion below for future reference This information can be found on your machine nameplate Product _________________________________________________________________________________ Model Number ___________________________________________________________________________ Code Number or Date Code_________________________________________________________________ Serial Number______________________________...

Страница 7: ... Bushings and Adapters A 7 Conduit Adapters A 7 Remote Sense Lead Specifications A 7 Installation of Field Installed Options A 7 Feeding Electrode and Brake Adjustment A 8 Drive Roll Pressure Setting A 8 Operation Section B Safety Precautions B 1 Duty Cycle B 1 General Description B 1 Recommended Processes B 1 Process Limitations B 1 Recommended Equipment Interface B 1 Accessories Section C Option...

Страница 8: ...red K1780 2 Power Feed 10 50 800 IPM 025 3 32 in 035 120 in 75 1200 IPM 025 1 16 in 035 5 64 in 1 27 20 3 m m 0 6 2 4 mm 0 9 3 2 mm 2 03 30 5 m m 0 6 1 6 mm 0 9 2 0 mm CONTROL BOX WIRE DRIVE AND COMPLETE UNITS SPEC TYPE INPUT POWER PHYSICAL SIZE TEMPERATURE RATING Dimensions Height Width Depth Weight Operating Storage K1780 2 Power 40 VDC 8 90 12 04 9 90 22 40 Lbs 20 to 40 C 40 to 40 C Feed 10 226...

Страница 9: ... loaded output cover near the bottom of the case front A work lead must be run from the negative power source output stud to the work piece The work piece connection must be firm and secure especially if pulse welding is planned Excessive voltage drops at the work piece connection often result in unsatisfacto ry pulse welding performance Connect a work lead of sufficient size and length per TABLE ...

Страница 10: ...IP switch 4 Using a pencil or other small object slide the switch to the on position for negative electrode polarity Conversely slide the switch to the off position for positive electrode polarity 5 Replace the cover and screws The PC board will read the switch at power up automatically adjust ing all control parameters for the selected polarity SHIELDING GAS CONNECTION The customer must provide a...

Страница 11: ... the desired gear ratio no changes need be made SELECTING THE PROPER GEAR RATIO See Specification Section A 1 for feed speed and wire size capabilities with high and low speed gear ratios To determine whether you should be using the high or low speed ratio use the following guidelines If you need to operate at wire feed speeds above 800 IPM 20 m m you will need to install the high speed gear large...

Страница 12: ... the screw on the left side of the Feed plate to 6 to 8 ft lbs with a 1 4 allen wrench 6 Tighten the screw on lower right face of feed plate tighten 6 to 8 ft lbs with a 1 4 allen wrench Set the High Low switch code on Wire Drive PC board which is located on the Power Wave 455 R and Power Wave 655 R Consult the Instruction Manual for proper power source settings CHANGING THE ANGLE OF THE FEED PLAT...

Страница 13: ...ries gun adapter should be followed when installing and configuring a gun The following guidelines are general procedures only that are not intended to cover all guns 1 Check that the drive rolls and guide tubes are prop er for the electrode size and type being used 2 Lay the cable out straight Insert the connector on the welding conductor cable into the brass conduc tor block on the front of the ...

Страница 14: ...tall gun adapters per the instructions shipped with it K1500 5 Oxo connection For any gun having an Oxo style threaded connector Install gun adapter per the instructions shipped with it CONDUIT ADAPTERS The K1546 1 and K1546 2 Adapter for use with Lincoln Magnum conduit K515 or 565 and E Beam conduit The K1546 1 is to be used for wire sizes 023 1 16 K1546 2 is to be used for wire sizes 1 16 120 Fo...

Страница 15: ... unless Cold Feed trigger mode is selected the electrode and drive mechanism are always Hot to work and ground and could remain Hot several seconds after the Gun trigger is released 5 Feed the electrode through the gun 6 Adjust the brake tension with the thumbscrew on the spindle hub until the reel turns freely but with little or no overrun when wire feeding is stopped Do not over tighten Drive Ro...

Страница 16: ... Feed Robotic Feeders must be used with PowerWave 455 R PowerWave 655 R or other Robotic PowerWave source These are the only power source to supply the correct operating voltage 40 volts DC and communication method Arc Link digital communications required by the Power Feed 10 Robotic B 1 OPERATION POWER FEED 10 ROBOTIC B 1 SAFETY INSTRUCTIONS Read and understand this entire section of operat ing i...

Страница 17: ...3 32 2 4 mm KP1505 3 32 Cored Electrode 0 030 0 8 mm KP1505 035C 0 035 0 9 mm KP1505 035C 0 040 1 0 mm KP1505 045C 0 045 1 2 mm KP1505 045C 0 052 1 4 mm KP1505 052C 1 16 1 6 mm KP1505 1 16C 0 068 1 7 mm KP1505 068 5 64 2 0 mm KP1505 5 64 3 32 2 4 mm KP1505 3 32 7 64 Lincore Hard Facing 2 8mm KP1505 7 64H 7 64 2 8mm KP1505 7 64 120 3 0mm KP1505 120 Aluminum Electrode 0 035 0 9 mm KP1507 035A 0 040 ...

Страница 18: ...phite grease Every six months check the motor brushes Replace them if they are less than 1 4 long SAFETY PRECAUTIONS ROUTINE MAINTENANCE Drive Rolls and Guide Tubes After feeding every coil of wire inspect the feed plate and drive rolls Clean them as necessary All drive rolls have two identical grooves The rolls may be flipped over to use the other groove See Procedure to Install Drive Rolls and W...

Страница 19: ...OSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause generally it states to contact your local Lincoln Authorized Field Service Facility If you do not understand or are unable to perform the Recommended Course of Action safely contact your local Lincoln Au...

Страница 20: ...osition of drive rolls relative to split wire guide groove 4 Drive rolls may not be seated properly 5 Gun cable dirty clean if neces sary 6 Worn drive roll 7 Electrode rusty and or dirty Cable frayed or poor sol der joint at work or electrode lug 8 Worn nozzle or cable liner Replace if necessary 9 Partially flashed or melted con tact tip Replace if necessary 10 Incorrect drive roll pressure Readju...

Страница 21: ...poor work connection 3 Loose electrode or work cable connections 4 Wrong polarity Make sure electrode polarity is correct for process being used 5 Gas nozzle extended beyond gun tip or wire stickout too long while welding 6 Poor gas shielding on processes requiring gas Check gas flow and mixture 1 Improper procedures or tech niques See Gas Metal Arc Welding Guide GS 100 2 Improper gas shielding Cl...

Страница 22: ...gram Welding may or may not vary from normal procedure Wire feeds properly Wire feed speed is consistent and adjustable but operates at the wrong speed 1 Tip overheating due to pro longed or excessive high current and or duty cycle welding Note A light application of high temperature antiseize lubri cant such as Lincoln E2067 Graphite Grease may be applied to tip of threads 1 The wire drive motor ...

Страница 23: ...ly It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to the Service Department for a replacement Give the equipment code number ...

Страница 24: ...F 2 DIAGRAMS F 2 POWER FEED 10 ROBOTIC POWER FEED 10 R DIMENSION PRINT ...

Страница 25: ...NOTES POWER FEED 10 ROBOTIC ...

Страница 26: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y de la tierra Ne laissez ni la peau ni des vête ments mouillés entrer en contact avec des pièces sous tension Isolez vous du travail et de la terre Berühren Sie keine stromführenden Teile oder Elektrode...

Страница 27: ...gute Be und Entlüftung des Arbeitsplatzes Mantenha seu rosto da fumaça Use ventilação e exhaustão para remover fumo da zona respiratória Turn power off before servicing Desconectar el cable de ali mentación de poder de la máquina antes de iniciar cualquier servicio Débranchez le courant avant l entre tien Strom vor Wartungsarbeiten abschalten Netzstrom völlig öff nen Maschine anhalten Não opere co...

Страница 28: ...s and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Products ...

Отзывы:

Похожие инструкции для Power Feed 10 Robotic K1780-2